GB
26- RESTORABLE THERMAL PROTECTION TRIPPING RESET
Should a current overload and/or a short-circuit occur in the electric plant of the machine, the restorable thermal switch trips stopping the electric motor. To reset the
restorable thermal switch, proceed as follows:
1) Press the "ON-OFF" switch (FIG. 5 - Ref. 3) on pos. "OFF (0)";
2) Press the restorable thermal push-button (FIG. 7 - Ref. 1);
3) Before restarting the machine wait some minutes.
SHOULD THE MACHINE AFTER HAVING PERFORMED THE RESET NOT SWITCH ON, THE CHARGED OPERATOR MUST COMPULSORY SEEK THE INTERVENTION OF THE MAINTE-
NANCE TECHNICAL ENGINEERS AND/OR OF THE AUTHORIZED DEALER.
27- EMERGENCY STOP
The switching-off of the machine can be performed by pressing the "ON-OFF" switch (FIG. 5 - Ref. 3) on pos. "OFF (0)". In order to avoid situations of imminent or close
hazard, the authorized operators must compulsorily perform the following operations:
1) PRESS THE "ON-OFF" SWITCH (FIG. 5 - REF. 3) ON POS. "OFF (0)" IN THE RIGHT TIME.
2) IMMEDIATELY INFORM THE "SAFETY MANAGER" OF THE EMERGENCY (IF THE MACHINE IS USED IN A COMPANY).
28- SWITCHING ON AFTER AN EMERGENCY STOP
Only and exclusively after having removed the emergency causes and having carefully assessed that the same have not caused damages and/or anomalies to the
machine, with the consent of the "Safety Manager" (in case the machine is used in a company), switch on the machine as described in par. 24.
29- ROUTINE MAINTENANCE
It includes all activities performed in order to maintain the proper use and operation conditions of the machine through different types of intervention (adjustments, visual
checks, cleaning of air filters, etc.) carried out by the authorized maintenance technical engineer at the established frequency.
THE AUTHORIZED OPERATORS MUST PERFORM EXCLUSIVELY THE OPERATIONS OF THEIR SPECIFIC COMPETENCE (SEE PAR. 5) AND WITH THE CONSENT OF THE COMPANY
SAFETY MANAGER (IF THE MACHINE IS USED IN A COMPANY).
THE AUTHORIZED OPERATORS ARE NOT ALLOWED TO LEAVE THE MACHINE UNATTENDED DURING ITS OPERATION AND DURING MAINTENANCE OPERATIONS.
FREQUENCY
POINT OF INTERVENTION
EVERY DAY
Safety devices
Power supply cable and plug
Tank
EVERY WEEK
Wheels
No.2 Air filters, front and rear side
7
30- SUPPLEMENTARY MAINTENANCE
FOR ANY SUPPLEMENTARY MAINTENANCE INTERVENTION, COMPULSORY REQUEST THE TECHNICAL ASSISTANCE TO THE MANUFACTURER OF THE AUTHORIZED DEALER.
31- DEMOLITION
32- SPARE PARTS
ORIGINAL SPARE PARTS FOR POSSIBLE REPLACEMENTS ARE TO BE REQUESTED EXCLUSIVELY TO THE MANUFACTURER OR TO THE AUTHORIZED DEALER.
IT IS STRICTLY FORBIDDEN TO REPLACE ANY COMPONENTS OF THE MACHINE WITH NOT ORIGINAL SPARE PARTS.
ROUTINE MAINTENANCE TABLE
It includes all activities performed in order to maintain the proper use and operation conditions of the machine through different types of interventions (adjust-
ments, replacements, etc.) carried out exclusively by the technicians of the manufacturer at the established frequency or in case of failure or wear.
When the machine is demolished, compulsorily observe the provisions of the regulations in force.
Separate the parts making up the machine according to the different construction materials (plastic, copper, iron, etc.).
TYPE OF INTERVENTION
Make sure that they are integral, properly installed and working.
Visual check of the wear state.
At every work cycle end lean the machine on the ground and drain the condensate from the tank, opening the
condensate valve (FIG. 1 - Ref. 5).
Tire pressure control. If necessary, inflate with compressed air up to max. 2.5 bar
Unscrew the screws (FIG. 6 - Ref. 1);
Remove the cover (FIG. 6 - Ref. 2);
Estract the filter (FIG. 6 - Ref. 3) and clean it with air;
Re-assemble the cover properly.
N.B.: REPLACE IN CASE OF CLEAR WEAR.
8