9 no enough heat wind
10. Showing "E5" on the
display
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator's electrical regulator may not be compatible with the stove's
electronics. The higher the quality of the generator, the greater the chance that it is compatible with
the stove.
Unqualified fuel
Blower speed is too low or
not running.
Heat exchange tubes or
flue pass are dirty.
Vent pipe is blocked
The door is opening, or
seal needs to be replaced
The are some leakages
81
Use the standard specially pellet.
Change the blower (Broken) or the
mother board is broken
Clean the heat exchange tubes or
flue pass.
Shut down the stove, check the
venting pipe
Close the door or change the seal
Check it and repair it. Adjust the
combustion fan's speed up to
offer more pressure in the
stove