Télécharger Imprimer la page

Hoover XP81XP25 Xarion Pro Allergy Care Manuel D'utilisation page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
IMPORTANT: Do not use the turbo and mini turbo nozzles on rugs with long fringes, animal
hides and carpet pile deeper than 15mm. Do not keep the nozzle stationary while the brush
is rotating.
CLEANER MAINTENANCE
Emptying the Dust Container
When the dust reaches the max level indicator in the container empty the dust container.
IMPORTANT: To maintain optimum performance do not allow the dust to sit higher than the
max level.
1.
Release the container carry handle by lifting the centre latch to detach the dust container
from the main cleaner and pull upward to remove. [14]
2.
Hold the dust container over a bin with one hand and with the other pull the dust
container catch to open the door and empty. [15]
3.
Close the dust container door and refit to the cleaner main body. To lock in place push the
container carry handle down until the latch connects with the main body of the cleaner.
Once correctly retained the carry handle will sits flush with the top of the cleaner.
Cleaning the washable filters
The cleaner is fitted with two blue hepa filter packs. To maintain optimum cleaning performance
regularly remove the filters and tap against the side of the bin to release dust. The filters should
be washed every 3 months or when the filter has excessive dust level.
IMPORTANT: Regularly check and maintain the filters.
IMPORTANT: Always ensure the filter pack is fully dry before use.
To access the Pre-Motor filter:
NOTE: Ensure the carry handle is at its down position before opening the filter door.
1.
Unlock the filter door by pulling the filter latch upwards. Open the filter door. [16]
2.
Remove the filter pack by pressing down on the retainer catch to release. The filter pack
will pop up. Slide the filter pack out. [17]
3.
Unlatch the filter pack frame.
4.
Remove the filter from the pack frame and wash the filter by hand using warm water. Do
not use hot water or detergents. Remove excess water from the filter and leave to dry
fully before reusing. [20]
5.
Reassemble to filter pack once fully dry and refit to the cleaner. Press on the top of the
filter to ensure it clips back into place.
To access the exhaust filter:
1.
Unlock the exhaust filter door by rotating the door along arrow indicated. [18]
2.
Remove the filter pack from recess. [19]
3.
Gently tap and wash the blue Hepa filter unit. Do not use hot water or detergents. Remove
excess water from the filter and leave to dry fully before reusing. [20]
4.
Reassemble filter pack once fully dry and refit to the cleaner.
IMPORTANT: Do not use the product without the filter pack fitted.
Cleaning the Airvolution separation unit
This cleaner uses the Airvolution separation system, unique to Hoover. If necessary the
Airvolution separation unit can be removed from the dust container and cleaned.
1.
Remove dust container from the cleaner by releasing the container carry handle to
detach the dust container from the main cleaner and pull upward to remove. [14]
2.
Place the dust container on a flat surface and unclip the clips from either side of the dust
container. [21]
3.
Using the dust container handle lift the dust container upper section containing the
separation unit from the lower section. [22]
4.
Use a cloth to remove excessive dust from the separation unit's surface. [23]
5.
Reassemble the dust container upper section. Push clips back to fully close the dust
container. [24]
6.
Refit the dust container to the cleaner. To lock in place push the container carry handle
down until the latch connects with the main body of the cleaner. Once correctly retained
the carry handle will sit flush with the top of the cleaner.
Removing a blockage
1.
Check if the dust container is full. If so refer to 'Emptying the dust container' .
2.
If the dust container is empty but suction is still low:
A.
Do the filters need cleaning? If so refer to 'Cleaning the washable filters' .
B.
Check if there is any other blockage in the system - Use a rod or pole to remove any
blockage from the extension tube or flexible hose.
C.
Check if pre-motor filter is fitted and filter door is closed.
D.
Check if the separation unit needs to be cleaned. Refer to 'Cleaning the separation
unit' .
3
GB

Publicité

loading