ENGLISH
Fireplace
Clearances
When using Bioethanol as a fuel source this model is suitable for
indoor and outdoor use.
Before installation ensure that the model is positioned in
accordance with the compulsory minimum clearances outlined
below.
If used indoors ensure that you pay attention to the Minimum Room
Size below:
XL900
110m
[3884ft
3
WARNING: Ensure that your fire is positioned away from
flammable materials and other sources of ignition at all times.
Pay very close attention to positioning the fire away from items
that may move as a result of wind and drafts. For example
trees/branches/paper and the like.
The base of the burner within the model must never come into
direct contact with flammable materials.
Side clearances to fixed and stable furniture items that are not
susceptible to movement (e.g lounges or patio furniture) must
remain a minimum of 600mm [23.6in] away from the flame at all
times.
Overhead clearances to items that are susceptible to movement
(e.g. Trees) must remain a minimum of 2000mm [78.7in] away from
the flame at all times.
These products feature 360º height-adjustable articulating feet.
Adjust the feet by turning them in either direction until you achieve a
perfectly level and stable model before operating.
Stainless steel will rust or corrode over time if contamination or
debris is not cleaned or removed immediately. Always use the
Burner Lid included with your model to avoid dust and debris from
accumulating inside the burner.
If you live in extreme weather conditions where accumulation of
snow is likely, use of the All Seasons Cover is imperative in order to
be covered by the warranty.
Due to the unique design of the Gin 90 Tables, sitting on or placing
excessive amounts of weight on the ends of the table is strongly
discouraged and may cause structural damage and/or cracking.
www.ecosmartfire.com
] per burner
3
[78.7]
2000mm
1. Outdoor Clearances
[59.1]
1500mm
[59.1]
1500mm
[23.6]
600mm
2. Indoor Clearances
Min 0.5''
CORRECT
(12.5mm)
Locating your appliance
Please do not remove the feet from the appliance, as they play an
important role in providing adequate airflow of the undersides.
1. Maintain a minimum air space of 12.5mm [0.5in] between the ground
surface and the underside of the appliance sidewalls by adjusting the
articulating feet up or down as necessary.
2. Do not place the appliance over grass, artificial turf, carpet, rock, or
any uneven surface.
DO NOT locate the appliance where it will get excessively wet or
submerged in water.
[23.6]
600mm
INCORRECT