Installation Manual
Remote sensor
Accessory parts
No.
Part Name
Q'ty
No.
Part Name
Remote
Wood screw
sensor
3
1
1
Installation
Manual
4
Screw
2
0.16" x 0.79"
2
(M4 x 20 mm)
Remote sensor installation place
requirements
• Do not install the remote sensor in a place where it will be exposed
to direct sunlight or outside air (near a window or the like).
• Install the remote sensor at a height of 3'3" to 4'11" (1 m - 1.5 m)
from the floor.
• Do not install the remote sensor behind obstacles, where it cannot
detect the room temperature.
• Install the remote sensor only in the room to be air-conditioned.
• Install the remote sensor vertically on the wall or the like.
• Do not install the remote sensor in a place where it will be
exposed to the direct discharge air from the air conditioner.
• Do not install the remote sensor on a wall whose temperature
greatly differs from the room temperature.
How to wire the remote sensor
 Connection diagram
* Use AWG14 - 20 (Use 0.5 -2.0 mm²
Remote sensor wiring
wire) wire.
(procured on site)
* Cannot use the closed end wire joint.
Terminal block
Remote sensor
A
A
for remote
B
B
controller wiring
Remote sensor
in indoor unit
terminal block
* Terminals A and B are non-polar.
NOTE 1:
The remote sensor wire should not be bundled with other
wires (mains, etc.), or installed with other wires in the
same conduit, as malfunction may result.
NOTE 2:
Install the remote sensor away from sources of electrical
interference and electromagnetic fields.
NOTE 3:
If electrical interference is unavoidable, countermeasures
such as appropriate filtering should be employed.
Remote Controller Wiring
Connection devices
Type
Q'ty
Remote controller wiring
(Indoor to Remote Controller
Shield wire
2 cores
wiring and remote sensor wiring)
To installation personnel - Electrical work and service
Model:
TCB-TC41U-UL
How to install the remote sensor
 Installation procedure
Q'ty
1.
2
Insert a flat head screw
driver or the like into the
slot at the bottom of the
2
remote sensor, and twist it
to remove the rear case.
2.
Secure the rear case on a
wall or the like using the supplied wood screws (2 pcs).
(Overtightening may damage the rear case or LCD.)
3.
Wire the remote sensor after checking the connector No. (A, B)
of the indoor unit to prevent miswiring.
(Applying AC 208 - 240 V causes damage.)
4.
Attach the remote sensor to the rear case by fitting its hooks into
the slits of the rear case.
 Installing the remote sensor on the wall
Rear case
Remote sensor
Wood screw (2 pcs.)
• Cut the wiring parts (shaded) at
the top of the remote sensor and
rear case using a knife, nipper, or
the like.
Remote sensor
(Rear)
• Protect the wires with the wire
cover.
Rear case
NOTE 1:
Leave a distance of at
least 1.18
30 mm)
" (
around the remote
sensor.
Size total length
Indoor A/B Terminal - Remote controller
Polarity
Terminal
Up to 656'2" (200 m)
Up to 984'3" (300 m)
IN CASE OF
IN CASE OF ONLY
INCLUDING
WIRED
WIRELESS
Non Polarity
Up to 656'2" (200 m) total length of control
wiring between indoor units
AWG14 - 20 (Use 0.5 -2.0 mm² wire)
Combination remote controller installation
requirements
 How to install
1.
Set the remote controller as the header.
(The factory default setting is header.)
• Set the room temperature sensor settings of the remote controller
to the factory default settings on the indoor unit side.
 Basic wiring diagram
• Controlling one indoor unit from a remote sensor and remote
controller
Remote sensor
(Follower)
A B
Terminal block for remote
controller wiring
Earth
Wall
Wiring part
Duct
Others
Locally
procured
Remote controller
(sold
separately)
(Header)
A B
Remote controller
wires
(procured on site).
A B
Indoor unit
* Terminals A and B
are non-polar.
DEB9609201 (EN)

Publicité

loading

Sommaire des Matières pour Toshiba Carrier TCB-TC41U-UL

  • Page 1 Installation Manual To installation personnel - Electrical work and service requirements Model:  How to install TCB-TC41U-UL Remote sensor Set the remote controller as the header. (The factory default setting is header.) Accessory parts How to install the remote sensor •...
  • Page 2 Manuel d’installation Pour le personnel d’installation - travail électrique et service combinaison de télécommandes Modèle:  Procédure d’installation TCB-TC41U-UL Capteur de télécommande Réglez la télécommande en tant que télécommande leader. (le réglage d'usine par défaut est leader.) Accessoires Comment installer le capteur de •...