Codage utilisé dans les procès-verbaux
MS power level = A15
Traffic channel = A16
Pre-att. defined by AUTOTEST = A20
RF output level (tester) = A21
Broadcast channel = A22
Pre-att. defined by MS TYPE = A23
6-30
Identifier
A15;
Result
0
Level change
0=PASS, 1=FAIL
Level
5
Power level
Network
4
1=P-GSM900 4=GSM1800
2=E-GSM900 5=GSM1900
3=R-GSM900 6=GSM850
Identifier
A16;
Result
0
Handover signaling
0=PASS, 1=FAIL
TCH
27
Traffic channel
Network
1
1=P-GSM900 4=GSM1800
2=E-GSM900 5=GSM1900
3=R-GSM900 6=GSM850
Identifier
A20;
RX value
1.5
Dimension dB
TX value
1.5
Dimension dB
Identifier
A21;
Value
-60.0
Dimension dBm
Identifier
A22;
Value
63
Network
4
1=P-GSM900 4=GSM1800
2=E-GSM900 5=GSM1900
3=R-GSM900 6=GSM850
Identifier
A23;
Channel ID
1
1=First channel
2=Second channel
3=Third channel
Channel type
2
1=Broadcast channel
2=Traffic channel
Channel
63
RX value
1.5
Dimension dB
TX value
1.5
Dimension dB
Network
1
1=GSM900
2=GSM1800
3=GSM1900
Willtek 4200