4. Connection
Check the identification plate at the back of the UPS to make sure that the power supply is
compatible with network voltage and that the device is powerful enough to protect the given
load. Plug the power cable of the UPS into a 2-pole, earthed outlet. Then, connect
computer-related devices to the back of the UPS.
5. On/Off
To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch
again. Make sure that the power switch is kept in the "ON" position, otherwise the UPS will
be disabled and your equipment unprotected in the event of power failure.
Note: For maintenance purposes, please turn the UPS on before the PC and other loads,
and turn it off after the connected loads are turned off.
6. DC Start
X3 EX units are equipped with an integrated DC start function. To start the UPS in the
absence of a power supply and with a full battery, simply press the button.
7. Power Saving Function
X3 EX range is equipped with a Power Saving Function. If no load connects to the UPS, it
will automatically shut down after 5 minutes to save energy during a power failure. The
Power switch must be kept in the 'ON' position, otherwise the UPS will be disabled and your
equipment will not be protected during a power failure.
8. Connect Modem/Phone/Network for surge protection
Connect a single modem/phone line to a surge protected "IN" outlet on the back panel of the
UPS unit. Connect the "OUT" outlet to the computer with another phone line cable.
Caution: The telephone line lightning arrester could be rendered inoperable if improperly
installed. This surge protection device is for indoor use only. Never install telephone wiring
during a lightning storm.
Note: This connection is optional.
8 . C O M P U T E R I N T E R F A C E
To prevent an abrupt computer system shutdown, connect a USB cable to your computer.
Then you can install and use the automatic shutdown software (Free download from web
site).
The USB communication port at the back of the UPS enables the computer to directly
control UPS status.
The main functions are as follows:
- Transmission of a visual alarm in event of power failure
- Automatic file closure prior to the battery going flat
- Computer & UPS shutdown
For more information, go to the website: www.infosec-ups.com
9 . B A T T E R Y
The battery is the only UPS component which is not in permanent use. It has a useful life of
approximately 3 to 5 years. However, frequent major discharges or exposure to
temperatures over 20 C will shorten its life span. We therefore recommend that users
recharge the battery once every 3 months when the unit is not in use in order to compensate
for natural discharging. UPS backup time will depend on the powered load, as well as the
age and condition of the batteries.