Page 1
inverter generator BE1200I BE2100I user manual...
Page 2
TABLE OF CONTENTS TABLE OF CONTENTS Safety Maintenance Introduction 25 Maintenance Safety Warnings 27 Spark plug inspection Safety Information 28 Carburetor adjustment 28 Engine oil replacement Description 29 Air filter 10 Description 30 Muffler screen and spark Arrester 11 Control Panel 31 Fuel tank filter Control Function 31 Fuel filter...
Page 3
Using the Operator’s manual The operating manual is an important part of your generator and should be read thoroughly before initial use, and referred to often to make sure The safety alert symbol ( ) is used with a signal word (DANGER, adequate safety and service concerns are being addressed.
Page 4
• NEVER operate the generator in an explosive atmosphere, near switches in the appliance.
Page 5
Instructions” in the Preparation section of this manual can be necessary. Please consult a qualified electrician for local regulations. A GFCI can be used only with generators that have the neutral wire internally bonded to the frame, and the frame properly grounded to the •...
Page 6
DESCRIPTION DESCRIPTION 1200I 1200I 2100I 2100I 1. Oil Warning Light 6. AC Receptacle 2. Overloading Indicator Light 7. DC Receptacle 3. AC Pilot Light 8. Ground (Earth) Terminal 1. Carrying Handle 6. Oil Filler Cap 4. ESC (Engine Smart Control) 9.
Page 7
(2) Engine switch\fuel valve\choke “ON”; Ignition circuit is switched on. Fuel is switched on. Choke is switched When the overload indicator light comes on and power generation stops, on. The engine can be running. proceed as follows: (3) Engine switch\fuel valve\choke “CHOKE”;...
Page 8
The fuel tank cap (2) is provided with an air vent knob to (1) stop fuel 4.6 Engine smart control (ESC) flow. The air vent knob must be turned to “ON”. This will allow fuel to flow to the carburetor and the engine to run. When the engine is not in use, ①...
Page 9
5.2 Engine oil TIP: Pre-operation checks should be made each time the generator is NOTICE used. • The generator has been shipped without engine oil. Do not start the engine without filling with the sufficient engine oil.
Page 10
Fuel is switched on. c. Choke is switched off TIP: The generator can be used with the rated output load at standard TIP: The choke is not required to start a warm engine. Push the choke atmospheric conditions.
Page 11
6.3 Alternating Current (AC) connection TIP: Turn off any electric devices. WARNING • Be sure any electric devices are turned off before plugging them in. 1. Turn the ESC to “OFF” (1). NOTICE • Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.
Page 12
• Be sure the ESC is turned off while charging the battery. of a generator. Otherwise, generator damage may occur. • Be sure to connect the red battery charger lead to the positive (+) battery terminal ,and connect the black lead to the negative (-) battery terminal.
Page 13
20hrs of months or 100hrs of • If the generator is to supply medical equipment, advice should first be operation every 50hrs operation of operation obtained from the manufacturer, a medical professional or hospital.
Page 14
• Do not operate the engine in a poorly ventilated room or other 2. Insert the handlebar (4) into the tool (5) and turn it counterclockwise enclosed area. Be sure to keep good ventilation in working area. The to remove the spark plug.
Page 15
7.2 Carburetor adjustment 6. Add engine oil to the upper level. The carburetor is a vital part of the engine. Adjusting should be left to our Recommended engine oil: SAE SJ 10W-40 company authorized dealer with the professional knowledge, specialized Recommended engine oil grade: API Service SE type or higher date, and equipment to do so properly.
Page 16
WARNING • Never use the gasoline while smoking or in the • The engine and muffler will be very hot after the engine has been run. vicinity of an open flame. Avoid touching the engine and muffler while they are still hot with any part of your body or clothing during inspection or repair.
Page 17
STORAGE TROUBLESHOOTING 8. STORAGE 8. Install the cover and tighten the screws. 9. Turn the fuel tank cap air vent knob to “OFF” after the engine has Long term storage of your machine will require some preventive completely cooled down. procedures to guard against deterioration.
Page 18
Instructions: First, connect the 2 inverters with 2 parallel cables as per the drawing above, and then start the inverters one at a time. At this time, the total rated power will be 3000W. Note: Ensure the cables are connected to the inverters correctly. If they are connected incorrectly, the inverters will not output any power and will need to be switched off and then on again after they are correctly connected.
Page 19
WARRANTY WARRANTY BE Pressure Inc. warrants that each new product will be free of any manufacture Warranty Claim Submission Procedure defects in workmanship for the set warranty period of the product. Warranty applies to the original purchaser of the product and cannot be transferred.
Page 20
THE POWER YOU NEED. If you need assistance with the assembly or operation of your Generator please call 1-866-850-6662...