Description
Output function selector
Auxiliary inputs
LEARN button
LEARN indicator light
Communication media
PLC => Mains borne signalling
Identification No.
Control buttons
Relay outputs
2 dry contacts
Operation
The modular multifunction switch has 4 different operating modes:
- Push-button —>
- Switch —>
- Latching relay —>
- Timer switch, from 5 s to 3 hrs
Function selection is separate from programming.
This product can be controlled by other products, where it becomes the Actor of a scenario. It can be an actor in
16 scenarios max. per output.
It cannot be a Leader.
Relay outputs 1 and 2 are automatically controlled when phase shows at auxiliary input 1 or 2, respectively.
Products that can be connected to auxiliary inputs include: push-buttons, switches, clocks, etc.
This product can communicate with radio products through the RF / PLC interface, Cat. No. 036 06 / 29.
(1) Learning: action of linking products to be controlled simultaneously from a central point.
This linking is performed by applying the scenario learning procedure on page 7.
(2) Scenario: corresponds to all the products (actors) that are linked to a control button.