SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
All numbers in parenthesis () refer to the index number from the parts breakdown.
Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic
system as a result of product shipment and handing. This step is to be completed without and weight on the
jack.
1. Turn the Release Valve counterclockwise to
release the pressure in the pressure in the pump
and hose.
2. Step on the pedal quickly for 10 times to
discharge the air out of the hydraulic system.
3. Firmly close the Release Valve and Fast-slow
Valve by turning it clockwise.
4. Step on the pedal to extend the piston rod for a
few distance.