13,3 V
ON
12,8 V
12,3 V
OFF
ATTENTION
The Voltage Control Module (VCM) in this kit is designed to be self switching at a pre-set voltage input.
With the engine started, the switched output (e.g. caravan fridge or alternative), pin 10, will switch on
at a preset figure of 13,4 volts.
When the engine is switched off, the switched output will remain live until the vehicle battery voltage
drops to a preset figure of approx 12,7 volts.
NOTE: The cut-off voltage depends on the condition of the vehicle battery, power consumption of the
fridge etc. In all cases, the cut-off figure is preset so the vehicle engine can be started at any time.
/