4
FUNCTION AND OPERATION
Installation position of the light is important: Ensure the light is mounted straight on the wall, otherwise, the induction distance may be limited.
When the light works at a height of 6.5 feet and temperature of 77 degrees Fahrenheit, the light would provide a maximum induction distance
of 40 feet and 180 degrees of induction range.
The sensor is more sensitive in passing across the light than going towards it.
Note: Working temperature of all the functions is -7°F ~95°F.
Time and Sensitivity setting:
TIME: Lighting time of the light. Use a slotted screwdriver, turn clockwise to increase, and counterclockwise to reduce, every quarter increases
about 60 seconds. Setting range is 20-180 seconds.
SENS: Sensitivity, induction distance of the light. Use a screwdriver, turn clockwise to increase, and counterclockwise to reduce. Default setting
induction distance is 10 meters.
Mode:
AUTO:
Day time off. At dusk, when human activity is sensed, light turns on at high brightness (100%). When human activity is NOT sensed (stationary
or leaves), the light keeps lighting for 20-180 seconds (as setting of TIME) then turn off. Default setting of lighting time is 60 seconds.
LOW LEVEL: NOT included in this function.
PC:
Day time off. Light turns on at dusk. Other settings are NOT included in this function.
AUTO+:
Note: Incandescent or dimmable LED bulbs must be used in this mode.
Day time off. At dusk, light turns and keeps on at low brightness (0%-50%, as setting of LOW LEVEL). When human activity is sensed, light
turns to high brightness (100%). When human activity is NOT sensed (stationary or leaves), light keeps high brightness for 60 seconds then
turn to low brightness.
LOW LEVEL: Low brightness of light. Use a slotted screwdriver, turn clockwise to increase, and counterclockwise to reduce. Setting range is
0%-50% brightness.
6'~10'
5'~40'
Motion
Motion
Sensor
Control panel
P. 9