Slacken the four motor fixing screws (A).
n
Shift the motor until the V-belt is tensioned to the
n
point where it can still be depressed by approx.
1-2 cm at the longest free position.
Retighten the motor fixing screws (A) and refit
n
the safety guard for the V-belt.
7.7 Cleaning the intake filter (1)
The intake filter prevents dust and dirt being drawn
in. It is essential to clean this filter after at least every
300 hours in service. A clogged intake filter will
decrease the compressor's performance
dramatically. Undo the two Allen screws (B). You can
then remove the filter from the two halves of the
plastic housing, tap it to remove the dirt, blast it down
with low-pressure compressed air (approx. 3 bar)
and re-insert it.(Fig. 18)
7.8 Storage
I mportant!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Important!
Store the compressor only in a dry location
which is not accessible to unauthorized persons.
Always store upright, never tilted!
7.9 Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
n
Article number of the machine
n
Identification number of the machine
n
Replacement part number of the part required
n
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
GB