7. ALARM SIGNALLING
Mess.
Cause
"P1"
Room probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"EA"
External alarm
"CA"
Serious external alarm
"dA"
Door Open
ALARM RECOVERY
Probe alarm "P1" starts some seconds after the fault in the related
probe; it automatically stops some seconds after the probe restarts
normal operation. Check connections before replacing the probe.
Temperature alarms "HA" and "LA" automatically stop as soon as
the temperature returns to normal values.
Alarms "EA" and "CA" (with iF=bA) recover as soon as the digital
input is disabled.
8. TECHNICAL DATA
Housing: self extinguishing ABS
Case: frontal 32x74 mm; depth 50 mm
Mounting: panel mounting in a 71x29 mm panel cut-out
Protection: IP20
Frontal protection: IP65
Connections: disconnectable terminal block ≤ 2,5 mm
Power supply: 230 Vac ±10%, 50/60 Hz
Power absorption: 3.5 VA max
Display: 2 digits, red LED, 14,2 mm high
Inputs: 1 NTC probe
Digital input: free voltage contact
Relay outputs: Output 1: SPDT 12 A 250 Vac
Output 2: SPST 5 A 250 Vac
Data storing: on the non-volatile memory (EEPROM)
Kind of action: 1B
Pollution grade: 2
Software class: A
Rated impulsive voltage: 2500 V
Overvoltage Category: II
Operating temperature: 0÷60°C
Storage temperature: -25÷60°C
Relative humidity: 20÷85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C
Resolution: 0,1°C or 1°C or 1°F (selectable)
Accuracy (ambient temp. 25°C): ±0,1°C ±1 digit
9. WIRING DIAGRAM
10. DEFAULT SETTING VALUES
LABEL
DESCRIPTION
REGULATION
-
Set point
Hy
Differential
LS
Minimum Set Point
US
Maximum Set Point
ot
First probe calibration
Instruction manual
Outputs
Compressor output
according to Cy e Cn
Outputs unchanged
Outputs unchanged
Outputs unchanged
All outputs OFF
wiring
2
RANGE
DEF.
LEV.
35°C
LS ÷ US
-
(95°F)
0.1 ÷ 25°C
2.0°C
L1
(1 ÷ 45°F)
(4.0°F)
-55°C ÷ SET
20°C
L2
(-67°F ÷ SET)
(68°F)
SET ÷ 99°C
50°C
L2
(SET ÷ 99°F)
(99°F)
-9.9 ÷ 9.9°C
0.0
L2
(-17 ÷ 17°F)
(0.0)
Outputs activation delay
od
at start up
AC
Anti-short cycle delay
Minimum time
Lt
compressor ON
Compressor ON time
Cy
faulty probe
Compressor OFF time
Cn
faulty probe
CH
Kind of Action
DISPLAY
CF
Measurement units
rE
Resolution (only for °C)
dy
Display delay
ALARMS
AA
Alarm configuration
Maximum temperature
AU
alarm
Minimum temperature
AL
alarm
AH
Alarm differential
Ad
Temperature alarm delay
Exclusion of temperature
dA
alarm at startup
At
Alarm showing mode
rA
Alarm relay mode
tb
Alarm relay silencing
OUTPUTS CONFIGURATION
o0
Output 1 configuration
o1
Output 2 configuration
AP
Alarm relay polarity
DIGITAL INPUT
iP
Digital input polarity
Digital input configura-
iF
tion
di
Digital input delay
OTHER
Pt
Parameter code table
rL
Firmware release
STRADA CA' BRUCIATA n°5
46020 PEGOGNAGA – MN – ITALY
TEL. +39(0)376-554511
FAX +39(0)376-550576
www.pavarinicomponents.com
- 6 -
0 ÷ 99 min
0
0 ÷ 50 min
4
0 ÷ 99 s
90
0 ÷ 99 min
1
0 ÷ 99 min
0
CL - Ht
CL
°C - °F
°C
dE - in
dE
0 ÷ 15 min
0
rE - Ab
rE
AL ÷ 99°C
10°C
(AL ÷ 99°F)
(18°F)
-55°C ÷ AU
10°C
(-67°F ÷ AU)
(18°F)
0.1°C÷25.5°C
1.0°C
(1°F ÷ 45°F)
(2.0°F)
0 ÷ 99 min
0
0 ÷ 99 min
60
AU - rS
rS
AU - rS
rS
n - y
n
nU / CP / Fn /
CP
AL / AU / db
nU / CP / Fn /
AL
AL / AU / db
CL - OP
OP
CL - OP
OP
EA / bA / do /
bA
Sb / AU / HC
0 ÷ 99 min
0
Read only
- - -
Read only
- - -
/
L2
L2
L2
L2
L2
L1
L1
L1
L2
L1
L1
L1
L1
L1
L2
L1
L1
L1
L2
L1
L1
L1
L1
L1
L2
L2