Install the Hood (Standard Installation)
N
OTE:
Two installers are recommended because of the weight of this hood.
1 ] Run house power cable between service panel and hood location. For hood with power cable
access located on back of hood, run the house power cable into the hood through the strain
relief previously installed in step 6 on page 11. For hood with power cable access located on top,
tighten the strain relief to the power cable before inserting the strain relief in the knockout hole.
2 ] Hang hood from (2) rear mounting screws previously installed. Slide hood back towards
wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood.
Tighten screws securely and maintain a hold on the hood until completing step 3.
3 ] Secure the hood to the cabinet using two (2) no. 8 x 5/8" round head wood screws (included
in parts bag). Insert one (1) screw per side, in the slot (as shown below). Attach power cable
to the hood using the strain relief.
Screw previously
tighten in step 2.
4 ] Connect ductwork to hood and use metal foil duct tape to make joints secure and air-
tight. Make sure the damper assembly (or round duct plate) enters the ductwork and that
the damper opens and closes freely.
BACK OF HOOD
DUCTED INSTALLATION ONLY
19