Télécharger Imprimer la page

Vito Agro VIIPMA Mode D'emploi page 18

Interrupteur de pression avec manometre

Publicité

Les langues disponibles

Les langues disponibles

DEFECT TYPE
The pump will not start
The pump does not stop
Intermittent pump operation (red led)
The pump is blocked
CAUSES THAT DEPEND ON PRESSURE
SWITCH
- Damaged electrical cable.
- The electronic board is damaged;
- The electronic board is damaged;
- Flow detector blocked in upper
position;
- Reset button locked;
- The pump does not provide
sufficient pressure.
- The electronic board is damaged;
- Pump with insufficient pressure;
- The electronic board is damaged;
- The pressure supplied by the pump
is less than the reset pressure;
CAUSES NOT DEPEND ON PRESSURE
SWITCH
- Power failure;
- Blocked pump;
- Inverted electric cables;
- Existence of leaks in the pipeline,
greater than the minimum flow of 2
L/min.
- The water flow is less than the
minimum flow of 2 L/min;
- Water failure;
- Suction problem;
- Water failure;
- Suction problem;

Publicité