DE GB NL FR
Frost
When the device has not been used for an extended period,
it must be protected against the effects of frost. Leave the
power supply on. When set to this position, the device main-
tains the water temperature at approximately 10 °C. If the
device is to be disconnected from the power supply, it must
be emptied completely in order to avoid the risk of damage
caused by freezing.
4.
MAINTENANCE
This device does not require any maintenance by the user.
Professional maintenance should always be carried out by
an expert.
As water expands when heated, the pressure will increase in the device vessel with the
connected hot water pipe(s). In order to limit this increase in pressure, a safety unit is
required. This is a combination of a check valve, which prevents hot boiler water from
flowing into the cold supply pipe, with a relief valve that limits the pressure in the device
to a maximum of 8 bar, and a Stop valve in front of the check valve in order to be able
to disconnect the device from the water mains.
The relief valve is provided with a discharge hose for discharging expansion water from
the device to the sewer.
The steel storage vessel is provided with an enamelled layer that prevents the formation
of corrosion. In case of damage to the enamelled layer, a magnesium anode mounted in
the storage vessel will make sure that the underlying steel is protected.
The magnesium anode protects the tank against corrosion. This is a cathodic process,
during which the anode slowly dissolves. The anode should therefore be inspected, and
replaced if necessary, by a recognized fitter every 2 years.
Check the functioning of the inlet combination by turning the large knob on the inlet
combination once a year, allowing water to flow out, and closing it immediately. This will
prevent the valve of the inlet combination from getting stuck. Also check the drain for
blockages. If it is blocked, unblock the drain or instruct a third party to do this.
If faulty, never try to repair the device yourself.
Please contact the nearest service specialist or the
party that supplied the device originally.
De-scaling
A service inspection should be performed by authorized and qualified technical staff
every year. De-scaling of the device during this inspection is highly recommended, es-
pecially when you live in an area with hard water exceeding 12°dH (German standard
of hardness). Higher water temperature will intensify calcification. It is therefore recom-
mended to set the device at maximum 55°C (energy-saving setting) in areas with ex-
tremely hard water >16°dH.
20