TROUBLE SHOOTING
Indicator LED State
Off (No water flow)
Off
(Water flow)
Red
Yellow Blinking
STANDARD TERMS & CONDITIONS
The sale and use of all Acuva products is governed by the Acuva Technologies Inc. Standard Terms
and Conditions of Sale and Use (the "Agreement"), a copy of which is available at www.acuvatech.com.
The Agreement contains important terms that, among other things, affect Acuva's liability and your
legal remedies against Acuva. Please read the Agreement carefully as, by purchasing the Acuva
product, you have agreed to be bound by the entire Agreement including the limited warranty,
limitations of liability and methods of resolving disputes. In the event of any inconsistency between
this manual and the Agreement, the Agreement shall prevail.
10
Fault Condition
No Fault
The unit is not powered
The flow direction is
reversed
The flow rate is too low
UV-LED fault
Low input voltage
Comments to User
-
Verify that the unit is connected to power
and that the input voltage is within
specifications (11-16V).
Ensure the inlet and outlet tubes are
connected to the respective fittings
marked "IN" and "OUT" on the device.
The flow sensor inside the unit requires a
minimal water flow to activate the system
(approx. 0.3 Lpm). Ensure there is enough
water pressure in the line to reach this
flow. (12 PSI)
Unplug and plug in the device's power
jack. If this fault persists, contact Acuva
for support.
Verify that the input voltage is above 11
volts.