Télécharger Imprimer la page

steute RF LDS SPOT-ST-NET Instructions De Montage page 2

Publicité

RF LDS SPOT-ST-NET / RF LDS SPOT-ST/BU-NET /
//
RF LDS ZONE-ST-NET / RF LDS ZONE-ST/BU-NET
Montage- und Anschlussanleitung / Funk-Laserentfernungsmesser
Mounting and wiring instructions / Wireless laser distance meter
Instructions de montage et de câblage / Télémètre laser sans fil
Istruzioni di montaggio e collegamento / Distanziometro laser wireless
Instruções de montagem e instalação / Medidor de distância a laser sem fio
Scan to watch
English
Use of the mounting and wiring instructions
All actions described in these instructions may only be performed by
qualified persons who have been trained and authorised by the
operating company.
1. Read and understand these mounting and wiring instructions.
2. Comply with the valid occupational safety and accident prevention
regulations.
3. Install and operate the device.
Selection and installation of devices and their integration in control
systems demand qualified knowledge of all the relevant laws, as well
as the normative requirements of the machine manufacturer. In case
of doubt, the German language version of these instructions shall
prevail.
Scope of delivery
Device, mounting and wiring instructions, carton.
Intended use
The device is designed for connection to the RF 96 BU SW868/SW915/
SW917/SW922-NET-LDS; the material no. depends on the frequen-
cy variant (on request). Up to four devices can be connected to an
RF 96 BU SW...-NET-LDS in total. Please use a 4-pole connecting
cable.
Mounting and wiring
With the help of the flange attached to the enclosure, the device can be
mounted on an even surface or a pipe. A bracket with a stand, Material
no. 1390766, offers additional flexible mounting options.
Connect the device as described for the initial operation in the
RF 96 BU SW868/SW915/SW917/SW922-NET-LDS mounting and
wiring instructions.
Accessory:
Name
RF LDS bracket with a stand
Cable 4pin M8x1 with plug/socket
Y-Distributor M8 plug / M8 socket 0° A-cod
Device
installation guide
Video tutorial
Material No.
1390766
1254189
1314363
Technical information
Due to its mode of operation, the device can detect all common ma-
terial surfaces with sufficient reflection. In individual cases, certain
material surfaces (such as rust) can lead to deviations from the set
switching distance.
The interval between the individual measurements, as well as the
switching distance, are stipulated by RF 96 BU SW...-NET-LDS and
configured.
Safety
Do not use the device in connection with other devices whose direct
or indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets. Do not look at
the ray with optical instruments.
N.B.
Subject to technical modifications. Reconstruction and alterations to
the device are not allowed. The described products were developed in
order to assume safety functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a plant or machine to
guarantee the correct general function.
Maintenance and cleaning
.steute recommends routine maintenance as follows:
1. Remove all dirt particles: Clean enclosure on the outside only.
Clean device in accordance with IP protection class. Clean with
a soft cloth and water or a mild detergent. Do not clean using
compressed air.
N.B.: PMMA protective screen must not be cleaned with alcohol!
2. Replace damaged parts.
3. Test the function.
Disposal
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
ESD
Ensure adequate ESD protection for all work that requires opening
the unit.
2 / 12