INSTALLATION REQUIREMENTS
CAPACITOR
(when required)
"A" = 30" minimum clearance between the
top of the cooking surface and the bottom
of an unprotected wood or metal cabinet; or
"A" = 24" minimum when bottom of wood
or metal cabinet is protected by not less than
1/4" thick flame retardant covered with not
less than:
WARNING:
Frame grounded to neutral of appliance through a link. If used in
a mobile home or if local codes do not permit grounding through
the neutral, disconnect the link from the neutral and use
grounding terminal or lead to ground unit in accordance with
local codes. Connect neutral terminal or lead to branch circuit
in usual manner.
DO NOT USE ground link when installed in Canada.
Use copper wire only.
If the appliance is to be connected by means of a cord kit, use
4-conductor wire for this purpose.
- No. 28 MSG steel sheet
- 0.015" stainless steet
- 0.024" aluminum, or
- 0.020" copper