All manuals and user guides at all-guides.com
Never use a heavy oil or an oil that forms gum.
Either will clog the small parts, restrict valve motion
and cause loss of efficiency. If the operation of the
Hammer becomes sluggish, pour 3 cc of a clean, suitable
cleaning solution into the air inlet and operate the tool for
30 seconds. Lubricate in the regular manner immediately
after flushing.
Model
Type of
Handle
115, 115- - EU
pistol grip
116, 116- - EU
pistol grip
117, 117- - EU
pistol grip
116H, 116H- - EU
pistol grip
117H, 117H- - EU
pistol grip
Tested in accordance with PNEUROP PN8NTC1.2 under load
H
♦ Tested in accordance with ISO8662- - 2
ISO3744
•
PLACING TOOL IN SERVICE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
SPECIFICATIONS
Impact/min.
Stroke Length
in.
5 000
1- - 5/8
3 500
2- - 5/8
2 000
3- - 1/2
3 500
2- - 5/8
2 000
3- - 1/2
3
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
FILTER
REGULATOR
(Dwg. TPD905- -1)
HSound Level
dB (A)
mm
Pressure
•Power
41
- - - - - -
- - - - - -
67
104.4
117.4
89
103.5
116.5
67
104.4
117.4
89
103.5
116.5
COMPRESSOR
♦Vibrations
Level
2
m/s
- - - - - -
30.0
46.4
30.0
46.4