FS12NPT Sink Kit with Two 1/2" NPT MIP x FIP Valves
EN
Leak Detection & Automatic Water Shut-off System Installation and Operating Manual
9.
Plug the pin on the end of AC
Adapter cord into the bottom of
the Control Panel. Then plug the AC
Adapter into a wall outlet. Green
indicator lights will start to flash,
showing you have power. NOTE: If a
nearby wall outlet is not available
you will need to purchase a thin low
voltage FloodStop 9 ft. AC Adapter
Extension Wire (Part #20091 –
FSAWAE9), available where you purchased your FloodStop System.
This wire extends the length of the AC Adapter cord. Max. extension
30 feet. CAUTION: Do not plug the AC Adapter into an extension cord.
10. FloodStop has a battery backup
system that allows the unit to
continue working in the event that
you have a power outage. To set
up the backup system, open the
front of the Control Panel and install
4 fresh AA alkaline batteries (not
included). The low battery indicator
light will now stop flashing and the
beep will stop. CAUTION: Replace
batteries once a year or sooner as necessary. If batteries need to
be changed sooner, a red low battery indicator light will flash, and a
beep will sound.
11. Turn on both the hot and cold-water
manual valves that supplies water
to the sink.
13. Gradually open the main water
supply valve.
12. Once the water has stopped
sputtering as the air has been bled
from the line, shut off shut off the
previously opened faucet from
step 2.
9
10
11
12
13
– 3 –
14. Press the OPEN button on the
FloodStop control panel to ensure
the FloodStop valve is open and
operational. Check for leaks.
HOW TO OPERATE YOUR CONTROL PANEL
Left button opens
1
FloodStop Valve.
Middle button closes
2
FloodStop Valve.
Right button mutes the
3
audible alarm that sounds
when a leak is detected.
NOTE: Mute button will not
silence the "low battery"
chirp (short beep every 45
to 60 seconds.)
TESTING YOUR FLOODSTOP SYSTEM
1.
Push the Open button to make sure FloodStop Valve is open.
When the FloodStop Valve is opening or closing, you will hear the
valve motor operating for a few seconds.
2.
Dip your finger in a cup of water and allow a drop or two to fall onto the
sensor. An audible alarm will sound, and the red LED will flash. In fact,
touching the sensor with your finger will typically trigger an alarm.
Push the Mute button to silence the alarm. Note that the red light will
continue to flash. This means the FloodStop Valve is closed and will
remain closed until you push the Open button.
NOTE: If water adequately evaporates from the Leak Sensor the
audible alarm will stop and the red LED will go solid. You will still need
to press the "open" button to rearm the system.
Before the FloodStop Valve can be opened, the Leak Sensor needs to be
dry. There is no need to unplug the unit when drying off the Leak Sensor.
Remove the paper sleeve from the Leak Sensor before performing
the water test. This will save you the time of waiting for the paper
sleeve to dry.
PRESSURE DROP DATA
The maximum pressure drop for this device is 2 psi at a flow rate of 5.5
GPM for NPS-3/4 and larger.