MANUAL Operation logic
The manual operation logic of the remote control PROTEO12-D
allows the direct control of the automation through the use of the
keys.
UP
transmits by radio an opening command
STOP
transmits by radio a stop command
DOWN transmits by radio a closing command
SELC
selects the desired radio channel (1 to 12)
SELG
selects the desired channel group (1 to 8)
To control the different automations it is necessary to save
PROTEO12-D in the different devices.
NOTE: Store the channels with a specific logic to simplify
the management of the automations and the creation of
groups.
To save PROTEO12-D in the control units, follow the procedure
described in the instruction manual provided with the control
units.
1. The remote must be in MANUAL mode.
If it is in AUTOMATIC mode, press SELC for 10 seconds,
the display shows (example):
2. Select the radio channel by pressing SELC or the group
through the SELG key and send the desired command using
the UP-STOP-DOWN keys
The display shows:
Setting the GROUPS
To set the automation groups to be controlled in MANUAL mode,
proceed as follows:
1. The remote must be in MANUAL mode.
If it is in AUTOMATIC mode, press SELC for 10 seconds,
the display shows (example):
All manuals and user guides at all-guides.com
2. Press the SELC key and select any channel
3. Press the SELC key for 10 seconds.
4. Using the UP and DOWN keys, select the ON (active) or OFF
5. Select the ON state for all the channels that must belong to
6. After setting channel 12, press MENU to confirm.
7. PROTEO12-D automatically exits the GROUP programming
8. To program additional groups, repeat the procedure
Deleting groups
1. Select the group to be deleted by pressing SELG
2. Hold down the SELG key until the channels of the group blink
17
The icon of Channel 1 blinks showing its state ON (active)
or OFF (inactive)
(off) state of the channel, press MENU to confirm and
proceed to the next channel.
the group.
NOTE: When the channels are activated they stay on
(example)
The channels that have been selected for the group blink
twice to confirm that the operation was successful
mode and displays the group you have just set
NOTE: PROTEO12-D allows to program 8 groups. When 8
groups have been programmed, to enter a new one you
must delete an existing group: see section "Deleting
Groups"
for 2 seconds and then go off. The group has been deleted.