WP1 INSTALLATION INSTRUCTIONS
Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We'd like to hear your comments.
Call the Marketing Department at 888-722-1000 or email: marketing@rclighting.ca
PHOTOCELL INSTALLATION
A PHOTOCELL MAY BE INSTALLED IN THE FIELD.
1. Remove door and reflector
2. Remove close up plug on top of fixture
3. Install photocell and wire as per diagram
4. Use photocell rated for your supply voltage
PHOTOCELL
CLEANING
CAUTION: Be sure fixture temperature is cool
enough to touch. Be sure power is off.
Clean reflector and refractor with a cloth moistened
with non abrasive glass cleaning solution.
TROUBLESHOOTING
1. Is the proper lamp is installed? Check the wattage
and ANSI code on the fixture label against markings
on the lamp. Refer to Replacement Lamp table
above for verification.
2. Make sure the lamp is not defective. Try a lamp
known to be in operating condition.
3. Check that the line voltage at fixture is correct. Refer
to wiring directions.
4. Is there voltage at the lamp socket? If there is no
voltage, check all connections.
5. Is the fixture grounded properly?
6. If used, is the photocell functioning properly?
Note: These instructions do not cover all details or variations
in equipment nor do they provide for every possible situation
during installation, operation or maintenance.
Easy Installation & Product Help
Tech Help Line
©2012 RC LIGHTING, LLC
Call our experts 888 722-1000
Northvale, New Jersey 07647 USA
WP1F-IN 0113 RCL
All manuals and user guides at all-guides.com
"COM"
FIXTURE
WP2FC
rclighting.ca
Visit our website for product info
RE-LAMPING
CAUTION: Prior to installing, check that the lamp is of
proper type and wattage. Observe lamp manufacturer's
recommendations on lamp operation, burning position and
ballast type.
1. Disconnect power
2. Make sure fixture and lamp are cool enough to touch.
3. Loosen four screws holding lens.
4. Open by swinging lens down, letting hinge hold lens.
5. Replace lamp.
6. Close lens and tighten screws.
REPLACEMENT LAMPS AND BALLASTS
RC Lamp
Wattage
Catalog#
High Pressure Sodium
35
LHPS35
50
LHPS50
70
LHPS70
100
LHPS100
Metal Halide
50PS
LMH50
70PS
LMH70
Compact Fluorescent
26
LCFL26
32
LCFL32
42
LCFL42
ANSI
RC Ballast
Code
Catalog#
S55
BHPSN35
S68
BHPSN50
S62
BHPSN70
S54
BHPSN100
M110
BMHN50
M98
BMHN70
Base
GX24q-3
BCFL42
GX24q-3
BCFL42
GX24q-4
BCFL42
email
Answered promptly sales@rclighting.ca