MFG
P/N
Molex
39012040
Molex
39012020
JST
XHP-2
J4 CAN BUS
J2 CAN BUS
Trunk Cable IN
LED ACTIVITY
Solid Green
OFF
Solid Red
Fast Flashing Green
Slow Flashing Green
Alternating Red & Orange
Alternating Green & Orange
All manuals and user guides at all-guides.com
MATING CONNECTORS
PIN P/N
0039000038, 0039000077, or Similar
0039000038, 0039000077, or Similar
SXH-001T-P0.6 or Similar
J4
J2
J7
Dip In 1 (GND)
DIP In 2 (GND)
J8
1 - Rain Sensor - Detect
2 - Rain Sensor - GND
NET LED STATUS
STATUS
Device is connected to network and communicating properly
Device has no power or has completely failed
Device has gone offline and is not connected to network
Device is attempting to make initial connection to network
(4times/sec)
Device was online but has not seen a valid network message for 5secs
(1time/sec)
Device has gone offline and is attempting to re-connect (within 30secs)
Device is currently online but has gone offline 2 or more times
DESC
4 Pos Mini-Fit Jr
2 Pos Mini-Fit Jr
2 Pos (2.5mm)
CAN PINOUT
FOR J2 and J4
4 - +12V
1 - CAN H
J7
ADDRESS CHART
ADDRESS
DIP IN 1
1
OPEN (OFF)
2
GND (ON)
Rain
3
OPEN (OFF)
Detector
4
GND (ON)
J5
Lid Motor Output 2
Lid
Motor
Lid Motor Output 1
Fan Motor Output 2
Fan
Motor
Fan Motor Output 1
4
MATE
J2 & J4
J7
J8
3 - GND
2 - CAN L
Trunk Cable OUT
The CAN network requires
two 120 Ohm terminator
resistors between CAN H
and CAN L.
With both terminators present
the resistance between CAN H
and CAN L should measure
60 Ohms when the network is
powered off.
DIP IN 2
OPEN (OFF)
OPEN (OFF)
GND (ON)
GND (ON)
ADDRESS NOTES:
The address of the module
can be set using the
Address DIP Switches (if
populated) or the address
can be set by grounding
the pins on J7 (if
populated)
as outlined in the
"ADDRESS CHART"