ENGLISH
Unit length
Volume flow - unrestricted
- at counter pressure -
1, 5 m bar
- at counter pressure - 2,5 m
- at counter pressure - 3,5 m
Connection of duct
Weight
Voltage
Motor output
Protective system
Type of explosion protection
Electric motor
ATEX specification Fan
Noise level at 1 m distance
10
TECHNICAL SPECIFICATION
bar
bar
110 V, 50 Hz single-phase,
COD. 79623
390 mm
1.0 m³/ sec
1.0 m³/ sec
0.8 m³/sec
0.6 m³/sec
flush for 300
20.5 kg
AC
0.37 kW
IP 55
EX-e-II- T3
II 2G c IIB T3
84.9 dB(A)
COD. 79624
390 mm
1.0 m³/ sec
1.0 m³/ sec
0.8 m³/sec
0.6 m³/sec
flush for 300 mm dia.
20.5 kg
230 V, 1 Ph., 50 Hz, AC
0.37 kW
IP 55
EX-e-II-T4
II 2G c IIB T3
84.8 dB(A)