The light-dark detector activates the relay output when the sensor detects the light level set with the circuit
potentiometer.
Includes light-dark mode switch, sensitivity adjustment potentiometer, working indicator led, protection against polarity
reversal and connection terminals.
OWER SUPPLY : Connect the 230 V AC power supply to the POWER terminal. Install a switch for circuit protection
and your own safety, according to CE standard. Before activating the switch, make the rest of the circuit connections.
Caution: Remember that there is 230 VAC in the circuit.
OPERATION : Connect the sensor to the indicated terminal. If the sensor connection cable exceeds 30 cm, you must
use shielded cable. Sensor has no polarity
After making all the circuit connections, turn on the power switch.
Move the sensitivity adjustment potentiometer to check how the relay connects and disconnects according to the light
level detected. The indicator led will light up when the relay is activated. With the light-dark switch, select work mode,
light mode will connect the relay when the sensor detects a light level higher than the set, in dark mode, it will connect
the relay when the sensor detects a light level lower than the set. To install outdoors, use a watertight plastic box to
protect the circuit from water and dust.
LIGHT - DARK DETECTOR
DETECTEUR DE LUMIÈRE - OBSCURITÉ
DETECTOR DE LUZ-OSCURIDAD
DETECTOR DE LLUM-FOSCOR
www.cebek.com
230 VCA
I-142 N
Technical characteristics
Voltage : 230 V. AC.
Medium Consumption : 1 W.
Sensor included : LDR
Operating Indicator Led : Yes.
Output type : Relay - NO / NC
Max. Output load : 7A ( 2A for inductive loads)
Sizes : 72 x 76 x 28 mm.
Weight : 153 gr.
Din rail : C -7565
-
sat@fadisel.com