5.2 Programming Relative humidity
5.2.1 Adjusting the Relative humidity value
When "HUM" is fl ashing, press
When "P01" is fl ashing, press
(P01 to P08 can be selected using ▲ and ▼)
When "CHA" is fl ashing, the ▲ and ▼ buttons can be used to select 'CHA' (change) or 'dEL' (delete).
If "CHA" is selected, press
Use the ▲ and ▼ buttons to set the hours between 0 and 23.
Press the
button, the minutes "00" will fl ash.
Use the ▲ and ▼ buttons to set the minutes between 0 and 59.
Press the
button, the desired humidity value will fl ash – "70".
Use the ▲ and ▼ buttons to set the desired value between 10 and 95.
When "P02" fl ashes, you can program further periods of time in the same manner.
If you do not wish to set further time periods press and hold the
Attention: If two or more times for the start of humidity control are identical, the error E3 appears on the display.
Note: It is not possible to enter turn-off times. The start time of, for example, P02 is the end time of P01. If only P01
is set, the programmed levels will be maintained over 24 hours. It is advisable to program at least two time periods to
differentiate day values and night values.
Example:
Programming for P01: 08:00 60 % RH, P02: 20:00 80 % RH means that the relative humidity will be maintained at
60 % between 8:00 and 20:00 and to 80 % between 20:00 and 8:00.
Programming for P01: 08:00 60 % RH, P02: to P08: --:-- means that the relative humidity will be maintained at 60 %
for 24 hours.
Attention: Ensure that unwanted settings are set to --:--. If you have exited a program period with 00.00, this will be
interpreted as a start or end time of 24.00 (midnight). Programming for P01: 08:00 60 % RH, P02: to P08: a setting
of 00:00 anywhere means that the relative humidity will be maintained at 60 % between 8:00 and 00.00 and to
70 % (automatic factory setting) between 00.00 and 8:00. Settings with a 00:00 time can be deleted by selecting
"dEL" (delete) instead of "CHA" (change) when entering the program level.