Screw
Figure 7
2.
Continuous Ventilation: For two speed fans wired for continuous ventilation with the
recommended AKS3 switch (not included). Properly ground the switch. Connect the Black
(Hot) wire from the supply to both the Blue wire of the fan and a black wire run to the
common terminal of the wall switch. Run 3 wires from the wall switch (not included) to the
fan. Connect the Yellow wire from the fan to the top terminal of the AKS3 switch. This is
the light control. Connect the Purple wire from the fan to the middle terminal of the AKS3
switch. This is the night light control. Connect the black wire from the fan to the bottom
terminal of the AKS3 switch. This is the fan control and closing the switch will change
from normal to high speed (Figure 8).
Supply from
house
Ground
(Green or
Bare)
Figure 8
Intermittent Ventilation: For two speed fans wired for intermittent ventilation with the
3.
recommended AKS4 switch (not included). Properly ground the switches. Run a wire from the
Blue wire in the fan to the Common terminal of one of the switches. Connect the Black wire
from the power source to the top terminal of the switch. This will turn the fan on and off. Run
a wire from the Black wire in the fan to the bottom terminal of the same switch. This is the fan
speed control and closing the switch will change from normal to high speed. On the second
switch run a Black (Hot) wire from the supply to the common terminal of the switch. On the
same switch run a wire from the Yellow wire in the fan to the top terminal of the switch. This
is the light control. Run a wire from the Purple wire in the fan to the bottom terminal of the
switch you just connected the yellow wire to. This is the night light control (Figure 9).
Supply from
house
Ground
(Green or
Bare)
Figure 9
NOTE: The fan's receptacle wires might need to be pulled outside compartment for connection.
Only pull the three loose wires outside of compartment. Additional wires will be present.
4.
Carefully tuck wires back inside wire compartment and replace wire compartment cover
securing with the screw that was removed earlier.
A210952014 Rev. F 5-14
Wire Compartment
Hot (Black)
Neutral (White)
Blue
Black
Yellow
Purple
Black
Hot (Black)
Neutral (White)
Yellow
Black
Switch
Switch
Blue
Black
SECTION 6
Completing the Installation
Cover
1.
Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan
be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.
If the fan's blower assembly was removed during the wiring process, reinstall the blower
by reversing the directions in Step 1b in Section 5 Wiring.
3.
Plug the fan's 5 pin quick connect motor cord into the receptacle on the side of the
wiring compartment cover and the light's 4 pin quick connect into the receptacle on
the top of the wiring compartment cover. These cords will only fit one way into the
receptacles (Figure 10).
Figure 10
4.
Install the included 26 watt fluorescent lamp into the lamp holder by lining up the pins on
the lamp base to the socket of the lamp holder and turning the lamp body clockwise until
the lamp snaps into place and is firmly seated in the lamp holder. Install a 4 watt maximum
type C7 (candelabra base) night light (not included) into the side lamp holder (Figure 11).
Lamp
Figure 10
5.
Install the reflector onto the grill by placing the slots on the side of the reflector over the
lens clips near the center of the grill. While squeezing the middle of the reflector, slide it so
that the plastic notches rest under the lens clips and the reflector feels secure (Figure 12).
Slot
Figure 12
www.airkinglimited.com
Night Light
Socket
Pin
Lamp Holder
Clip
3 of 12