Télécharger Imprimer la page

Abus FUMO50010 Manuel D'instructions page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
TECHNICAL DATA
Dimensions (WxHxD)
Weight
Displays
Operating temperature
Environmental class
Humidity
Protection class
Radio frequency
Transmission power, wireless
Wireless range
Wireless identification code
Security level
Tamper protection (detection/protection)
Power supply
'Low battery' error message
Power consumption
Voltage monitoring
Type of power supply
Conformity
EU Directives
All manuals and user guides at all-guides.com
130 x 155 x 42 mm
223 g (without batteries), 274 g (with batteries)
3 status LEDs
-10°C to +55°C
II (EN50131-1 §7, EN50131-3 §7)
max. 94% (non-condensing)
IP34 (indoors)
868.6625 MHz
max. 10 mW
500 m outdoors
16.777.214 (224 – 2) variants
2 (EN50131-1 §6, EN50131-3 §6)
Typ B (EN50131-3 §8.7)
6–15 V DC, external PSU
Backup Power Supply
2 AA alkaline batteries
(Duracell Procell MN1500, Duracell Industrial ID1500, Energizer E91)
< 2.7 V ('low battery' threshold)
22 (TX), 17 (RX) mA @ 12V DC, nominal
20 (TX), 15 (RX) mA @ 13,8V DC, nominal
48 (TX), 38 (RX) mA @ 5V DC (USB), nominal
50 (TX), 40 (RX) mA @ 3V DC (Batterien), nominal
During operation with an external power supply, a fault report is sent
to the alarm control panel as soon as this is interrupted. The wireless
repeater is then automatically powered by the batteries. The corresponding
notification on the alarm control panel informs the user about this. The
batteries are permanently monitored. If the voltage is below the lower
threshold of 2.7 V, a fault report is sent to the alarm control panel and the
user is informed.
Type B (50131-1 §9 and 50131-6 §4.1)
external power supply via power supply unit and batteries inserted
as a backup power supply
Power supply compliant with EN50131-1:2006+A1:2009 9.2 and EN50131-6 if
installed correctly together with Secvest Wireless Alarm System FUAA50xxx
The device is compliant with EN 50131-1, EN50131-3:2009, EN50131-5-3 and
EN50131-6 security level 2 if installed correctly together with Secvest Wireless
Alarm System FUAA50xxx.
RED: 2014/53/EU, EMC: 2014/30/EU, RoHS: 2011/65/EU WEEE: 2012/19/EU, ErP:
2009/125/EC, Low Voltage: 2014/35/EU, General Safety: 2001/95/EC
Signal strength/wireless reception range
Software version

Publicité

loading