Télécharger Imprimer la page

Publicité

Liens rapides

All manuals and user guides at all-guides.com
Multiservice
Gateway
AT-iMG606BD
Installation Guide
613-000298 Rev. B

Publicité

loading

Sommaire des Matières pour Allied Telesis AT-iMG606BD

  • Page 1 All manuals and user guides at all-guides.com Multiservice Gateway AT-iMG606BD Installation Guide 613-000298 Rev. B...
  • Page 2 All manuals and user guides at all-guides.com Copyright © 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Microsoft and Internet Explorer are registered trademarks of Microsoft Corporation. Netscape Navigator is a registered trademark of Netscape Communications Corporation.
  • Page 3 Declaration of Conformity Manufacturer Name: Allied Telesyn, Inc. Declares that the product: Multiservice Gateway Model Numbers: AT-iMG606BD This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the...
  • Page 4 All manuals and user guides at all-guides.com Immunity EN55024 Electrical Safety EN60950, UL 60950 ( Laser Safety EN60825...
  • Page 5 All manuals and user guides at all-guides.com Translated Safety Statements Important: Appendix B contains translated safety statements for installing this equipment. When you see the , go to Appendix B for the translated safety statement in your language. Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die Installation dieses Geräts.
  • Page 6 All manuals and user guides at all-guides.com...
  • Page 7 Planning the Installation ..................31 LAN Ports..................... 31 Fiber Optic Uplink Port ................. 31 Console Port ....................31 Unpacking the AT-iMG606BD Multiservice Gateway.......... 32 Installing the AT-iMG606BD Multiservice Gateway..........33 Warranty Registration..................42 Chapter 3: Troubleshooting ................43 Appendix A: Technical Specifications ............45 Physical Specifications..................
  • Page 8 All manuals and user guides at all-guides.com Contents 100Base-FX Fiber Optic Uplink (WAN) Port ............47 Appendix B: Translated Safety Statements ............49...
  • Page 9 Figure 20: Removing the Plug from the Fiber Optic Port ........39 Figure 21: Mounting the Gateway on the Base ........... 40 Figure 22: AT-iMG606BD Multiservice Gateway Installed on the Base ....40 Figure 23: Plugging in the Power Cord ............... 41...
  • Page 10 All manuals and user guides at all-guides.com Figures...
  • Page 11 All manuals and user guides at all-guides.com Tables Table 1: Safety Symbols ..................14 Table 2: LAN Port LED Descriptions ..............23 Table 3: System LEDs ..................24 Table 4: Twisted Pair Cabling and Distances ............. 31 Table 5: 10/100Base-TX Port Pinouts ..............46 Table 6: 100Base-FX Fiber Optic Port ...............
  • Page 12 All manuals and user guides at all-guides.com Tables...
  • Page 13 All manuals and user guides at all-guides.com Preface This guide contains the installation instructions for the AT-iMG606BD Multiservice Gateway. This preface contains the following sections: “Safety Symbols Used in this Document” on page 14 “Where to Find Web-based Guides” on page 15...
  • Page 14 All manuals and user guides at all-guides.com Preface Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data.
  • Page 15 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Where to Find Web-based Guides The installation and user guides for all Allied Telesyn products are available in portable document format (PDF) on our web site at www.alliedtelesyn.com. You can view the documents online or download them onto a local workstation or server.
  • Page 16 All manuals and user guides at all-guides.com Preface Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales and corporate information. Online You can request technical support online by accessing the Allied Telesyn Knowledge Base: http:// Support kb.alliedtelesyn.com.
  • Page 17 All manuals and user guides at all-guides.com Chapter 1 Overview The AT-iMG606BD Multiservice Gateway supports Internet and Internet video in one compact unit. This chapter contains the follows sections: “Features” on page 18 “Gateway and Base Units” on page 19 “Ports”...
  • Page 18 All manuals and user guides at all-guides.com Chapter 1: Overview Features The features of the AT-iMG606BD Multiservice Gateway include: Six 10/100Base-TX Ethernet (LAN) ports One 100Base-FX single fiber bidirectional uplink (WAN) port Tagged-based VLAN Layer 2 and Layer 3 QoS...
  • Page 19 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Gateway and Base Units Gateway Unit Figure 1 shows the front view of the AT-iMG606BD Multiservice Gateway. Figure 1. Front View Figure 2 illustrates the location of the LAN ports on the AT-iMG606BD Multiservice Gateway.
  • Page 20 All manuals and user guides at all-guides.com Chapter 1: Overview Base Unit The AT-iMG606BD Multiservice Gateway is shipped with a 3-piece base, shown in Figure 4, that holds the fiber optic cable connection and secures the unit to the wall.
  • Page 21 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Ports The AT-iMG606BD Multiservice Gateway has eight ports: Six 10/100Base-T Ethernet (LAN) ports with RJ-45 connectors One 100Base-FX fiber uplink (WAN) port with a simplex SC connector One Console port for local management...
  • Page 22 The port pin assignments can be found in “10/100Base-TX Port Pinouts” on page 46. 100Base-FX The 100Base-FX fiber uplink (WAN) port on the AT-iMG606BD Multiservice Gateway features a simplex SC Fiber Uplink connector. The gateway port must be connected to a fiber (WAN) Port optic port that is IEEE 802.3ah-compliant and whose...
  • Page 23 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide LEDs The AT-iMG606BD Multiservice Gateway has two LEDs for each LAN port and three LEDs for the unit as a whole. LAN Port Each LAN port has two LEDs as shown in Figure 5.
  • Page 24 All manuals and user guides at all-guides.com Chapter 1: Overview System LEDs The system-level LEDs are shown in Figure 6 and described in Table 3. Power VoIP System Figure 6. System LEDs Table 3. System LEDs State Description The gateway is receiving power and the voltage is within the acceptable range.
  • Page 25 12 VDC +25%/-20% and double insulation between the main line and the SELV output. Refer to Chapter A, “Technical Specifications” on page 45 for the power specifications for the AT-iMG606BD product. Note If you purchase the AT-RG005G battery backup unit, you must also order the AT-RG008 power cable.
  • Page 26 All manuals and user guides at all-guides.com Chapter 1: Overview Console Connection The console connection is available for accessing the software on the AT-iMG606BD Multiservice Gateway using the AT-RGCOMSOLECABLE-00 console cable (not included with the gateway). Contact your Allied Telesyn sales representative to order the cable.
  • Page 27 “Reviewing Safety Precautions” on page 28 “Selecting a Site for the Gateway” on page 30 “Planning the Installation” on page 31 “Unpacking the AT-iMG606BD Multiservice Gateway” on page 32 “Installing the AT-iMG606BD Multiservice Gateway” on page 33 “Warranty Registration” on page 42...
  • Page 28 All manuals and user guides at all-guides.com Chapter 2: Installation Reviewing Safety Precautions Please review the following safety precautions before you begin to install the AT-iMG606BD Multiservice Gateway. Note When you see the , go to the Appendix B for translated safety statements.
  • Page 29 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Warning: Only trained and qualified personnel are allowed to install or to replace this equipment. Caution: Do not install in direct sunlight, or a damp or dusty place.
  • Page 30 All manuals and user guides at all-guides.com Chapter 2: Installation Selecting a Site for the Gateway Observe the following requirements when choosing a site for your gateway: Do not expose the gateway device to moisture or water. The power supply for the gateway should be located near the unit and should be easily accessible.
  • Page 31 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Planning the Installation This section describes the cables necessary for the installation of an AT-iMG606BD Multiservice Gateway. LAN Ports Table 4 contains the cabling specifications for the LAN ports.
  • Page 32 All manuals and user guides at all-guides.com Chapter 2: Installation Unpacking the AT-iMG606BD Multiservice Gateway To unpack the gateway perform the following procedure: Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesyn.
  • Page 33 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide Installing the AT-iMG606BD Multiservice Gateway To install the AT-iMG606BD Multiservice Gateway, perform the following procedure: Remove all equipment from the package and store the packaging material in a safe place.
  • Page 34 All manuals and user guides at all-guides.com Chapter 2: Installation Select a wall location and mark three hole locations for the anchors, as shown in Figure 8. Make sure that you install the base so that the top edge is level. Wall anchor holes Figure 8.
  • Page 35 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide On the back of the cover, note the eight possible locations where you can remove a “knockout” in order to thread the cable into the base, as shown in Figure 10.
  • Page 36 All manuals and user guides at all-guides.com Chapter 2: Installation Wrap the cable in a figure eight around the spindles in the center and finally around the U-shaped spindle, as shown in Figure 12. U-shaped Spindle Figure 12. Wrapping the Cable around the Spindles You should have between 2 to 3 inches of cable at the end.
  • Page 37 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide 10. Mount the cover over the base, aligning the screw holes with the posts, as shown in Figure 14. Figure 14. Aligning the Screw Holes with the Posts 11.
  • Page 38 All manuals and user guides at all-guides.com Chapter 2: Installation 12. Remove the cover from the post, as shown in Figure 16. Figure 16. Removing the Cover from the Post 13. Position the SC connector in the slot of the post so that the key is facing up, as shown in Figure 17.
  • Page 39 Figure 19. Figure 19. Installing the Connector Cover 17. Remove the plug from the fiber optic port on the AT-iMG606BD Multiservice Gateway, as shown in Figure 20. S O L C O N P O W Figure 20.
  • Page 40 All manuals and user guides at all-guides.com Chapter 2: Installation 18. Slide the AT-iMG606BD Multiservice Gateway onto the base, matching the grooves, until the fiber optic cable snaps into place in the port and the gateway is aligned with the base, as shown in Figure 21.
  • Page 41 Figure 23. If you are using the battery backup unit, you must use the AT-RG008 power cable. (The AT-RG005G battery backup unit must be earthed.) Refer to Chapter A, “Technical Specifications” on page 45 for AT-iMG606BD power specifications. S O L C O N P O W Figure 23.
  • Page 42 All manuals and user guides at all-guides.com Chapter 2: Installation Warranty Registration After installing your gateway, you can register your product by completing the enclosed warranty card and sending it to Allied Telesyn.
  • Page 43 All manuals and user guides at all-guides.com Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the AT-iMG606BD Multiservice Gateway in the event that a problem occurs. Review the following possible scenarios and the suggested solutions. Problem: The PWR LED is off.
  • Page 44 All manuals and user guides at all-guides.com Chapter 3: Troubleshooting...
  • Page 45 All manuals and user guides at all-guides.com Appendix A Technical Specifications Physical Specifications Dimensions: 240 mm x 145 mm x 60 mm (9.44 in x 5.7 in. x 2.36 in.) Weight (Gateway Only): 408 g (.9 lb.) Weight (Gateway and Base): 635 g (1.4 lb.) Environmental Specifications...
  • Page 46 All manuals and user guides at all-guides.com Appendix A: Technical Specifications Safety and Electromagnetic Emissions Certifications EMI/RFI: FCC Part 15, Class B; EN55022 Class B Immunity: EN55024 Electrical Safety: EN60950, UL60950 ( 10/100Base-TX Port Pinouts This section lists the pinouts for the RJ-45 connector for the 10/100Base-T LAN ports.
  • Page 47 All manuals and user guides at all-guides.com AT-iMG606BD Multiservice Gateway Installation Guide 100Base-FX Fiber Optic Uplink (WAN) Port Table 6 lists the specifications for the 100Base-FX fiber optic port. Table 6. 100Base-FX Fiber Optic Port General Maximum Distance 20 km µ...
  • Page 48 All manuals and user guides at all-guides.com Appendix A: Technical Specifications...
  • Page 49 All manuals and user guides at all-guides.com Appendix B Translated Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
  • Page 50 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Laser Safety Notices Warning: Class 1 Laser product. Warning: Do not stare into the laser beam. Electrical Safety Notices Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside.
  • Page 51 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Warning: As a safety precaution, install a circuit breaker with a minimum value of 15 Amps between the equipment and the DC power source. Always connect the wires to the LAN equipment first before you connect the wires to the circuit breaker.
  • Page 52 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Warning: The power source for the gateway unit should be located near the unit and should be easily accessible. Caution: To allow proper cooling of the gateway device, make sure that the air flow around the unit and through its heatsink cooling fins on the rear is not restricted.
  • Page 53 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Warning: Do not look directly at the fiber optic cable ends or inspect the cable ends with an optical lens. Warning: This unit might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing the unit.
  • Page 54 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Telecommunications Compliance Notices Warning: When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electronic shock, and injury to persons, including the following: Do not use this product near water, for example, near a bathtub, washbowl, kitchen sink, or laundry tub in a wet basement or near a swimming pool.
  • Page 55 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Lasersicherheitshinweise Achtung: Laserprodukt der Klasse 1. Achtung: Blicken Sie nicht in den Laserstrahl. Elektrische Sicherheitshinweise Achtung: Um Stromschläge zu vermeiden, darf die Abdeckung nicht entfernt werden. Die Ausrüstung enthält keine benutzerwartbaren Teile.
  • Page 56 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Achtung: Als Sicherheitsvorkehrung sollte ein Überlastschalter mit einem minimalen Nennwert von 15 Ampere zwischen der Ausrüstung und der Gleichstromversorgung installiert werden. Vor dem Anschluss der Kabel am Überlastschalter sollten stets zuerst die Kabel an die LAN-Ausrüstung angeschlossen werden.
  • Page 57 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Vorsicht: Bei der Innenraummontage des Gateway-Geräts ist darauf zu achten, dass es in einer staubfreien Umgebung installiert wird. Es sollte ein Installationsort gewählt werden, an dem die Ports am Gateway-Gerät gut zugänglich sind, um das Anschließen und Abtrennen von Kabeln zu erleichtern und den freien Blick auf die LEDs zu ermöglichen.
  • Page 58 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Zur zuverlässigen Stromversorgung des Geräts sollte ein dedizierter Stromkreis oder Netzfilter und Stabilisator (Power Conditioner) verwendet werden. Achtung: Das Chassis kann schwer und schwierig zu heben sein. Allied Telesyn empfiehlt, bei der Rackmontage des Chassis Hilfspersonal heranzuziehen.
  • Page 59 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Telekommunikationskonformitätshinweise Achtung: Bei der Verwendung Ihrer Telefonausrüstung sollten zur Reduzierung der Brand-, Stromschlag und Verletzungsgefahr stets grundsätzliche Sicherheitsrichtlinien, einschließlich der folgenden, befolgt werden: Verwenden Sie dieses Produkt nicht in der Nähe von Wasser, zum Beispiel in der Nähe einer Badewanne, einer Waschschüssel, eines Spülbeckens, eines Waschbottichs, in einem nassen Kellerraum oder in der Nähe eines...
  • Page 60 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Avisos de seguridad láser Atención: Producto láser de clase 1. Atención: No mire el rayo láser. Avisos de seguridad eléctricas Atención: Para evitar la electrocución, no quite la tapa. La unidad no contiene piezas que pueda reparar el usuario.
  • Page 61 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Atención: Como medida de seguridad, instale un disyuntor con un valor mínimo de 15 A entre el equipo y la toma de alimentación CC. Conecte siempre los cables a los equipos de la LAN antes de conectarlos al disyuntor.
  • Page 62 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Atención: La toma eléctrica de la unidad de puerta de enlace debe estar situada cerca de la unidad y ser de fácil acceso. Precaución: Para permitir la refrigeración adecuada del dispositivo de puerta de enlace, asegúrese de no limitar la circulación de aire alrededor de la unidad ni a través de las aletas de refrigeración del radiador de la parte trasera.
  • Page 63 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Atención: Esta unidad puede tener más de un cable de alimentación. Para reducir el peligro de electrocución, desconecte todos los cables de alimentación antes de manipular la unidad. Atención: Este equipo sólo debe ser instalado y manipulado por personal convenientemente formado y cualificado.
  • Page 64 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Avisos de conformidad de telecomunicaciones Atención: Cuando utilice su equipo telefónico, deberá adoptar las siguientes precauciones de seguridad básicas para reducir el riesgo de incendio, descarga electrónica y lesiones: No utilice este producto en zonas húmedas;...
  • Page 65 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Avis de sécurité laser Avertissement: Produit laser de classe 1. Avertissement: Ne pas observer directement le rayon laser. Avis de sécurité électrique Avertissement: Pour éviter tout risque d’électrocution, ne pas déposer le capot.
  • Page 66 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Avertissement: Par mesure de sécurité, installer un coupe- circuit d’une intensité minimum de 15 ampère entre l’équipement et la source d’alimentation en courant continu. Toujours connecter les fils à l’équipement de réseau local avant de les raccorder au coupe-circuit.
  • Page 67 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Attention: Si le périphérique servant de passerelle est installé à l’intérieur, s’assurer qu’il se trouve dans en endroit non poussiéreux. Le site doit offrir un accès aisé au port du périphérique servant de passerelle afin de faciliter la connexion et la déconnexion des câbles, tout en permettant d’observer aisément les voyants.
  • Page 68 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Utiliser des circuits d’alimentation ou des unités de conditionnement dédiés pour fournir une alimentation électrique fiable à l’équipement. Avertissement: Le châssis peut être lourd et difficile à soulever. Allied Telesyn recommande de demander de l’aide pour installer le châssis dans un rack.
  • Page 69 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Télécommunications – Avis de conformité Avertissement: Les précautions élémentaires de sécurité doivent être systématiquement respectées en utilisant l’équipement téléphonique pour réduire les risques d’incendie, d’électrocution et d’accident corporel, notamment: Ne pas utiliser ce produit près d’une source d’eau, telle qu’une baignoire, un lavabo, un évier ou un baquet dans un sous-sol humide ou près d’une piscine.
  • Page 70 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Indicazioni sulla sicurezza laser Avvertenza: Prodotto laser Classe 1. Avvertenza: Non fissare il raggio laser. Indicazioni sulla sicurezza elettrica Avvertenza: Per evitare scosse elettriche, non rimuovere la copertura. All'interno non sono presenti componenti utilizzabili dall'utente.
  • Page 71 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Avvertenza: Per precauzione, installare un salvavita con un valore minimo di 15 ampere tra l'apparecchiatura e la fonte di alimentazione CC. Collegare i cavi all'apparecchiatura LAN prima di collegarli al salvavita.
  • Page 72 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Avvertenza: La fonte di alimentazione dell'unità gateway deve essere posizionata vicino all'unità, in un luogo facilmente accessibile. Attenzione: Per consentire il raffreddamento appropriato del dispositivo gateway, verificare che il flusso d'aria attorno all'unità...
  • Page 73 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Avvertenza: Questa unità potrebbe disporre di più cavi di alimentazione. Per ridurre il rischio di scosse elettriche, scollegare tutti i cavi di alimentazione prima di iniziare la manutenzione dell'unità. Avvertenza: Solo personale esperto e qualificato può...
  • Page 74 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Indicazioni per la conformità con le norme sulle telecomunicazioni Avvertenza: Quando si utilizza l'apparecchiatura telefonica, per ridurre il rischio di incendio, scosse elettriche e danni alle persone, è necessario seguire alcune precauzioni di base per la sicurezza, ad esempio: Non utilizzare il prodotto in prossimità...
  • Page 75 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Лазерная безопасность Внимание: лазерный продукт, класс 1. Внимание: Не смотрите прямо в лазерный луч. Электрическая безопасность Внимание: Для предотвращения электрического шока, не снимайте кожух. Внутри нет частей, подлежащих обслуживанию...
  • Page 76 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Внимание: Для безопасности установите прерыватель для максимальной силы тока 15 ампер между оборудованием и источником постоянного тока. Всегда подсоединяйте провода к сетевому оборудованию (LAN) перед тем, как присоединять кабели к прерывателю. Не...
  • Page 77 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Внимание: Источник питания должен быть невдалеке от установки, и к нему должен быть удобный доступ. Предостережение: Для хорошей вентиляции шлюзовой установки, позаботьтесь, чтобы вокруг установки и через вентиляционные решетки мог свободно циркулировать воздух.
  • Page 78 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements Внимание: Не смотрите прямо на торцы волоконно- оптического кабеля и не инспектируйте торцы кабеля с помощью оптической линзы. Внимание: Установка может быть оборудована несколькими проводами питания. Перед техническим обслуживанием...
  • Page 79 All manuals and user guides at all-guides.com AT-MG606BD Multiservice Gateway Installation Guide Телекоммуникационное соответствие Внимание: При использовании телефонного оборудования, всегда следует обращать внимания на требования безопасности для снижения риска пожара, поражения током и ранения, в том числе: Не используйте оборудование рядом с водой – например ванной, раковиной...
  • Page 80 All manuals and user guides at all-guides.com Appendix B: Translated Safety Statements...