SECTION 2
ELECTRIC SHOCK CAN KILL! Make
sure that all primary input power to the
power source and wire feeder has been
disconnected at the wall (line) discon-
nect switch or circuit breaker before
making the following connections.
All manuals and user guides at all-guides.com
IV INSTALLATION
MMI PANEL INSTALLATION
MMI panel installation differs between the DuraDrive 4-30 and DuraDrive 4-48.
1. Switch the POWER toggle switch on the DuraDrive front panel to the
"OFF" position. Turn "OFF" ALL power to the power source and
DuraDrive wire feeder using the main power disconnect switch and
unplugging the power source.
DuraDrive 4-30
a.
Remove the six screws holding the right side control cabinet
panel and lift up the hinged left door access to the drive stand
compartment.
b.
Unplug the wire harness exiting the back of the MMI panel
cover from the DuraDrive main control PCB.
c.
Remove the four plastic panel nuts that secure the MMI panel
corners.
d.
Pull the MMI panel forward until the wire harness and plug(s)
clear the front panel of the DuraDrive control cabinet.
DuraDrive 4-48
a.
Remove the six screws of the right side control cabinet cover.
b.
Remove five of the six screws on the Left side cover of the
feeder that are easily accessible.
c.
For access to the panel screw behind the drive stand, remove
the "Tilt Adjustment" knob above the drive stand and tilt the
drive stand to the top position (see Figure 2-1). Remove the
sixth screw (see Figure 2-2).
d.
Lift up the hinged drive stand door to the top position with the
motor and gearbox attached (see Figure 2-3).
e.
Unplug the wire harness exiting the back of the MMI panel
cover from the DuraDrive main control PCB (see Table 2-1).
f.
Remove the four plastic panel nuts that secure the MMI panel
corners.
g.
Pull the MMI panel forward until the wire harness and plug(s)
clear the front panel of the DuraDrive control cabinet.
2.
Install the new MMI panel into the DuraDrive front panel and secure
with the finger nuts from the old MMI panel.
3.
Route the wire harness and plug so they enter the control PCB
compartment (right side).
4.
Connect the MMI harness plugs to the DuraDrive motor Control PC
board as shown in Figure 3-1 and Table 2.
5.
Replace the DuraDrive Control cabinet side panels.
10
INSTALLATION