Télécharger Imprimer la page

DENIA DF-100 Instructions D'utilisation Et D'entretien page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
USAGE AND MAINTENANCE INSTRUCTIONS
You have purchased a DENIA product. Apart from correct maintenance, our
woodstoves require an installation strictly in accordance with present legislation. Our
products comply to the EN 13229 European norm, however it is very important for
you to know how to correctly use your woodstove following the recommendations we set
out.
For this reason, before installing our product you must read this manual carefully and
follow the usage and maintenance instructions.
The fireplace transmits warmth twofold: first by radiation warmth through the big surface of
the vitroceramic glass and second by convection warmth. The convection warmth is genera-
ted by recuperating the warmth generated on the outer walls of the combustion chamber
and by ways of leaving a small area around the fireplace warm air streams are created
which exit the fireplace through a grill at the front.
INSTALLATION
You have purchased a wood burning stove with a vermiculite insulated combustion chamber.
Do not remove the vermiculite boards!!!!!
IMPORTANT: The installation of this fireplace has to be done by a qualified professional.
IMPORTANT:
All local regulations, including those referring to National and European standards, need
to be complied with when installing the fireplace.
SMOKE PIPE
- The fireplace may not be installed into a chimney system shared with other appliances.
- Install the tube connections carefully, the connections should be sealed with a refractory
putty to prevent soot from falling through the joints, until you reach the exterior exit.
Connect the first pipe of the smoke outlet to the fireplace with a minimum 40 mm overlap.
- The installation of the smoke outlet must be as vertical as possible, avoiding the use
of joints, angles and deviations that could cause a malfunction of the fireplace.
- If the installation is connected to a masonry chimney pipe we recommend that its internal
size should not be too big because this would cause the smoke to get too cold which pro-
duces the smoke to return into the fireplace. In case the chimney pipe is too big it' s re-
commended that the pipes should reach the exterior exit.
- In the smoke outlet is via tubing only, at least three meters of vertical tubing are recommended.
- It is recommended to put a " h at on the last tube in case it reaches the exterior of your home.
PLACEMENT
- The fireplace has to be installed at a site that supports its heavy weight and everything
surrounding it must be of noncombustible material and/or be well insulated.
- You must foresee accessibility for the cleaning of the fireplace, flue and chimney.
- While the fireplace is functioning keep anything away from it that could be damaged by
heat like furniture, draperies, paper, clothing,... You should keep a minimum safety
distance of 80cm.
- This fireplace must be installed in a well ventilated area. We recommend you have at
least one window that can be opened in the room where the fireplace will be installed.
4

Publicité

loading