GB
INSTALLATION GUIDE
Savtec is the suction shut-off valve for Sunfab's SLPD pumps.
Savtec is intended for installations where the power take off is not disen-
gaged during transport.
INSTALLATION
Connect the valve with the flange halves
➁
Connect the short oil line
the under side of the pump.
Use seal washers on each side of the nipple.
Complete the routing with a 13 mm (½") hose
of the pump directly to the oil tank. The connection to the oil tank should
be below the oil level.
Otherwise see SL pump installation guide 7006.
AIR CONTROL
➄
The angled nipple
is the compressed air connection for opening the
➅
valve. The straight nipple
is routed to a protected location.
Nipple diameter: 6 mm.
Sunfab reserves the right to make changes in design and dimensions without notice. Printing and typesetting errors reserved.
© Copyright 2017 Sunfab Hydraulics AB. All Rights Reserved.
Sunfab Hydraulics AB, Box 1094, SE-824 12 Hudiksvall, Sweden. Tel: +46 650-367 00, Fax: +46 650-367 27, E-mail: sunfab@sunfab.se Web: www.sunfab.com
➀
. Tighten the screws alternately.
➂
using banjo nipples
between Savtec and
➃
between the upper side
is the ventilation connection for a hose which
80 Nm
GB/US | SE | DE | ES | FR | IT | NO | FI | DK | PT | NL | PL | GR
2
38 mm (1½")
Q
= 65 l ⁄min
max
50 mm (2")
Q
= 120 l ⁄min
max
64 mm (2½")
Q
= 185 l ⁄min
max
75 mm (3")
Q
= 265 l ⁄min
50
(2")
mm
max
64
(2½")
mm
3
20/20, 28/28, 35/35, 46/46, 53/53
40/20, 56/28, 64/32
SAVTEC
24 Nm
150 Nm
60 Nm
60 Nm
7007INT1711 REV 1.3 1/4