2
Description of motor
Type
F 416 Ex
F 416-1 Ex
F 416-2 Ex
3
Technical specifications
Motor
Kind of
type
motor
F 416 Ex
Compressed
F 416-1 Ex
air motor
F 416-2 Ex
Ambient temperature: -20°C - + 40°C
3.1
Sound level measurement
Sound level: 83-90 dB(A) measured with standard silencer
Sound power level L
Depending on the design of the pump and the load of the pump, and thus the engine,
the sound varies.
4
Installation and commissioning
> Screw a silencer onto the compressed air motor.
> Install a fine filter silencer or an exhaust hose.
> Place the motor on the pump.
Risk of injury!
Explosion hazard!
8 / 20
Speed control
Via service unit
Via service unit
Via ball valve
Power output
470 W / 6 bar
Air consumption:
14 l/s
: 95 dB(A)
WA
Separate engine from compressed air supply before installation.
Only operate the pump when the union nut between the pump
and the motor is tightened hand-tight.
Possible risk of crushing fingers at the thread of the silencer
when installing the silencer.
Risk of injury due burring at the thread cut. Wear appropriate
protective gloves during installation and disassembly
Therefore, produce equipotential bonding before commissioning
the pump in hazardous areas!
Attachment compressed-air motors F 416 ...
On/off switch
Yes
Via service unit
Via ball valve
Explosion-
protection marking
Registration number
II 2G Ex h IIC T6 Gb
PTB Reg. No.
02 ATEX D022-3
Weight
0.9 – 1.4 kg