Télécharger Imprimer la page

Maytag HRX75XQRSCGA Guide D'utilisation page 8

Publicité

Les langues disponibles

Les langues disponibles

GET TO KNOW YOUR WATER HEATER - GAS MODELS
A
Vent Pipe
B
Draft Hood
C
Anode
D
Hot Water Outlet
E
Outlet
F
Water Connections
G
Gas Supply
H
Manual Gas Shut-off Valve
I
Ground Joint Union
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
TO VENT TERMINATION
ON ROOF
* ALL PIPING MATERIALS TO BE
SUPPLIED BY CUSTOMERS.
** CLOSED WATER SYSTEMS ARE THOSE WITH
BACK FLOW PREVENTION DEVICES INSTALLED
IN THE INLET WATER SERVICE LINE.
TYPICAL INSTALLATION
J
Drip Leg (Sediment Trap)
K
Inner Door
L
Outer door
M
Union
N
Inlet Water Shut-off Valve
O
Cold Water Inlet
P
Inlet Dip Tube
Q
Temperature-Pressure Relief Valve
R
Rating Plate
Y
THERMOSTAT
SHIELD
(OPTIONAL)
FIGURE 7.
8
S
Flue Baffle(s)
T
Thermostat
U
Drain Valve
V
Pilot and Main Burner
W
Flue
X
Drain Pan
Y
Thermostat Shield (optional)
(T) THERMOSTAT
(V) PILOT & MAIN BURNER- NATURAL GAS
(V) PILOT & MAIN BURNER - PROPANE GAS
THERMOCOUPLE
PILOT
BURNER
MAIN
BURNER

Publicité

loading

Ce manuel est également adapté pour:

Hrx75cqrscga