OBSERVED FAULT
Blower does not start when you slide
the switch to the "on" position.
Battery runs slowly.
Battery discharges quickly.
Battery not charging.
All manuals and user guides at all-guides.com
Unplug blower/sweeper from power source before servicing. Severe
POSSIBLE CAUSE
1. Battery not installed properly.
2. Battery not charged
1. Battery is nearly depleted.
1. Battery not fully charged.
2. Battery worn and will not hold
a charge.
1. Charger not plugged in.
2. Battery not fully inserted into
charger base.
3. Charger cord not properly connect-
ed to charger base.
4. Charger damaged.
SAVE THESE INSTRUCTIONS
REMEDY
1. Verify proper installation of bat-
tery.
2. Insure battery is charged per re-
quirements.
1. Recharge battery completely.
1. Recharge battery completely.
2. Replace battery.
1. Plug charger into 120V 60 Hz AC
source.
2. Insure battery is inserted
correctly in charger base.
3. Insure batter cord is fully in
inserted into charger base.
4. Replace charger.