ELECTRIC PRUNING SHEARS
K. Screw the M5 hexagon socket
countersunk head counterclockwise
as shown.
15.4. TOOL CALIBRATION
If a replacement motor or drive plate is required, the pruners need to be
recalibrated.
Follow next steps to perform the calibration:
•
Remove the upper and lower blades.
•
Insert the battery.
•
Hold down the trigger and keep it pressed. Press the POWER switch again.
•
Maintain the trigger pressed for more than 10 s.
•
Release the trigger when you hear the motor turning.
•
The electric motor rotates during calibration. When the motor stops
turning the calibration is complete.
•
Reassemble the blades as indicated in chapter 15.3.
K
L. Reduce the friction between the
two blade planes by adding oil as
shown in the figure.
www.gruposanz.es
L
85