GB
Thank you for purchasing our digital scale
(MV-100
/MV-1000). With normal care and proper
treatment, this scale will provide years of reliable service.
General Maintenance and Care
1. Avoid exposure to extreme heat or cold. Also avoid any kind of moisture. Always allow your scale
to acclimate to normal room temperature before use.
2. Keep your scale in a clean and dry environment. Dust, dirt, moisture, vibration, air currents and
proximity to other electronic equipment may have an adverse effect on the accuracy and reliability of
the scale.
3. Handle the scale with care. Gently apply all items to be weighed on the tray top. Although this
scale is designed to be quite durable, avoid rough treatment, as this may permanently damage the
internal parts. Always avoid shaking and dropping. This is a precision instrument and should be
handled with extreme care.
Specification and Function
1. Capacity/Accuracy: 100g / 0.01g or 1000g / 0.1g
2. Units: g, oz, ozt, dwt, ct, gn
3. Key function: ON/OFF, TARE, MODE
4. Display: LCD display with backlight
5. Auto off: 180 seconds if inactivity
6. Power: 2 AAA batteries
7. Operation Temp: 10 to 30 deg C
Operation
1. Place the scale on a leveled surface & press "ON/OFF" key to turn on the scale or power it off.
2. Wait until the LCD display shows zero, then press "MODE" key to choose the weighing unit.
3. Place the item to be weighed on the platform and wait until the reading is stable.
Tare Function
1. Turn on the scale as described above.
2. Place the "tare item" on the platform. Press "TARE" key and wait until the LCD displays zero.
3. Scale can now be used for weighing. Add the "net-weight-item".
Calibration
1. When the scale is turned off, press the "ON/OFF" key to turn on the scale. Wait until the LCD
display shows "0.0" or "0.00".
2. Press and hold the "MODE" key until the display shows "CAL", then release the button. Press the
"MODE" key again and the required calibration weight will flash on the display. Place the required
weight onto the center of the platform.
3. The LCD display reads "PASS" and come back to the normal weighing mode. Calibration is now
complete.
Warning
1. "LO": Low voltage. Please replace the batteries.
2. "O-Ld": Overload. Please remove item quickly to protect the scale.