OPTIONAL ACCESSORIES
○ Single sequential actuation mechanism kit (Code No.
887916)
○ Pneumatic Tool Lubricant
.8 oz. (25 cc) oil feeder
4 oz. (120 cc) oil feeder
1 quart (1 ltr) can
NOTE: Accessories are subject to change without any
obligation on the part of HiKOKI.
APPLICATIONS
○ Making cases for furniture
○ Creating walls and other areas in mobile homes.
○ Making doors and windows for home construction.
BEFORE OPERATION
Read section titled "SAFETY" (pages 4 – 8).
Make sure of the following before operation.
WORKING ENVIRONMENT
● No fl ammable gas, liquid or other fl ammable
objects at worksite.
● Clear the area of children or unauthorized
personnel.
AIR SUPPLY
● NEVER use reactive gases or
● Never connect Stapler to pressure which
potentially exceeds 200 psi (13.7 bar 14 kgf/cm
if a regulator fails.
● Never use non relieving coupler on Stapler.
1. Power source
○ Use only clean, dry, regulated compressed air as a
power source for this Stapler.
○ Air compressors used to supply compressed air to
this Stapler must comply with the requirements of
the latest version of ANSI Standard B 19.3 "Safety
Standard For Compressors For Process Industries."
... sold separately
(Code No.877153)
(Code No.874042)
(Code No.876212)
WARNING
DANGER
other
bottled
Explosion may occur.
WARNING
○ Moisture or oil in the air compressor may accelerate
wear and corrosion in the Stapler.
Drain daily.
2. Filter-Regulator-Lubricator
○ Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar 0 – 8.5 kgf/cm
○ Filter-regulator-lubricator units supply an optimum
condition for the Stapler and extend the Stapler life.
These units should always be used.
Filter .............The fi lter removes moisture and dirt
Regulator ......The regulator controls the operating
Lubricator .....The lubricator supplies an oil mist to the
Stapler
Side
gases.
3. Air hose
Compressed air supply hoses shall have a minimum
working pressure rating equal to or greater than the
pressure from the power source if a regulator fails, or
150 psi (10.4 bar 10.6 kgf/cm
4. Air consumption
Using the Air consumption table and the Air
)
2
compressor size formula, fi nd a correct compressor
size.
Air consumption table
Operating pressure
Air consumption
).
2
mixed in compressed air.
Drain daily unless fi tted with an
automatic drain.
Keep the fi lter clean by regular
maintenance.
pressure for safe operation of the Stapler.
Inspect the regulator before operation
to be sure it operates properly.
Stapler.
Inspect the lubricator before operation
to be sure the supply of lubricant is
adequate.
Use HiKOKI pneumatic tool lubricant.
Regulator
Compressor
Side
Lubricator
), whichever is greater.
2
psi
80
(bar)
(5.5)
(6.2)
(kgf/cm
)
(5.6)
(6.3)
2
ft
/cycle
.019
.023
3
(ltr/cycle)
(.55)
(.64)
English
Filter
90
100
(6.9)
(7)
.025
(.73)