Télécharger Imprimer la page

Stid ATX Notice D'installation page 4

Masquer les pouces Voir aussi pour ATX:

Publicité

Les langues disponibles

Les langues disponibles

ATX / ATX2-R11-A-E01-xx
1
2 3 4 5 6
0 Vdc
+Vcc
Code / D0
Data / D1
Clock
Terminal block Connector
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN
62368-1) for the main supply.
Main power supply:
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data)
Protection:
IP66 level
When the reader is switched on, the orange LED and the buzzer are activated. It is possible to shut it off by removing the jumper located just
nearby the buzzer.
The operating mode LED can be driven by the remote system with a 0 Vdc respectively on the « Green », « Red » (TTL) or driven by the
communication protocol (RS232/RS485).
For Data signals, if data pull-up resistors are not installed on the host unit, it is necessary to add 10k pull-up resistors to Vin (power supply
voltage).
Not connected: filtering is activated, the code is transmitted every two seconds. If a new card is presented it is immediately transmitted.
Connect to 0V: filtering does not activate.
▪ Power off the reader.
▪ Connect "Setup" input to 0 Vdc.
▪ Power on the reader. The led will then blink slowly orange, indicating the reader is in configuration mode. In this mode, the communication
speed is 9600 bauds, and there is no parity control. The Carriage Return is necessary, and the reader is inactive.
▪ Transmit the desired options. (cf. Spec_Protocole_5C_V1.5_EN for RS232 or Spec_Protocole_7S_V2.0_EN for RS485).
▪ Power off the reader.
▪ Disconnect "Setup" from 0 Vdc.
▪ Power on the reader again: the new configuration is activated.
ATEX & IECEX reader
Installation procedure
7 8 9 10
Red
Green
Mode
Type R11
(Wiegand)
1
2
3
Data 0 (D0)
4
Data 1 (D1)
5
Clock
6
Mode
7
Green Led
8
Red Led
9
NC
10
NC
+12 Vdc
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1104X05 - Page 3 sur 15 - Ed. 25/05/2023
Lecteur ATEX & IECEX
Notice d'installation
ATX / ATX2 125 kHz
ATX / ATX2-R12-A-E01-xx
1
2 3 4 5 6
7 8 9 10
0 Vdc
+Vcc
Setup
Tx
Rx
Type R11
(Clock & Data)
0 Vdc
+Vcc (+12 Vdc)
Code
Data
Clock
Mode
Green Led
Red Led
NC
NC
Power Supply Characteristics
Characteristics
Buzzer / LED
TTL Pull-ups
Input "Mode"
Input "Setup"
ATEX & IECEX lectores
Manual de instalación
ATX / ATX2-R13-A-E01-xx
1
2 3 4 5 6
0 Vdc
+Vcc
Setup
L +
L -
Type R12
Type R13
(RS232)
(RS485)
Setup
Setup
Tx
L +
Rx
L -
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
US
FR
ES
7 8 9 10

Publicité

loading

Ce manuel est également adapté pour:

Atx2