Télécharger Imprimer la page
Masquer les pouces Voir aussi pour VMB1BLS:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

All manuals and user guides at all-guides.com
VMB1BLS
SHORT MANUAL
1-KANAALS ROLLUIKSTURING
(UNIVERSELE MONTAGE)
ONE CHANNEL BLIND MODULE
(UNIVERSAL MOUNTING)
MODULE DE CONTRÔLE
1 CANAL POUR VOLETS
ROULANTS
(MONTAGE UNIVERSEL)
b a c

Publicité

loading

Sommaire des Matières pour Velbus VMB1BLS

  • Page 1 All manuals and user guides at all-guides.com VMB1BLS SHORT MANUAL 1-KANAALS ROLLUIKSTURING (UNIVERSELE MONTAGE) ONE CHANNEL BLIND MODULE (UNIVERSAL MOUNTING) MODULE DE CONTRÔLE 1 CANAL POUR VOLETS ROULANTS (MONTAGE UNIVERSEL) b a c...
  • Page 2 all-guides.com...
  • Page 3 ⑪ terminaison Overige elementen Other elements Autres éléments ⑫ LED PS (voeding) ⑫ LED PS ⑫ LED PS (alimentation) ⑬ LED up ⑬ LED up ⑬ LED monter (power supply) ⑭ LED down ⑭ LED down ⑭ LED descendre www.velbus.eu...
  • Page 4 All manuals and user guides at all-guides.com www.velbus.eu...
  • Page 5 All manuals and user guides at all-guides.com 1. VELBUS 230 V AC MOTOR 24 V DC MOTOR www.velbus.eu...
  • Page 6 All manuals and user guides at all-guides.com 2. STANDALONE 1 PUSH BUTTON 230 V AC MOTOR 24 V DC MOTOR www.velbus.eu...
  • Page 7 - 2 x knipperen, pauze, 2 x knipperen, enz.: communicatiefout (enkel indien aangesloten op Velbus data bus en adres ≠ FF) - 3 x knipperen, pauze, 3 x knipperen, enz.: voedingsspanning te laag - 4 x knipperen, pauze, 4 x knipperen, enz.: voedingsspanning te hoog...
  • Page 8 all-guides.com...
  • Page 9 2. STANDALONE GEBRUIK de VMB1BLS gewoon gevoed worden met 12..18 V DC / 100 mA (aansluitingen ⑦ en ⑧) zonder de BUS H ⑨ De VMB1BLS kan ook gebruikt worden als standalone rolluikbesturing (zonder Velbus installatie). In dat geval moet en BUS L ⑩...
  • Page 10 • dimensions: 72 x 59 x 24 mm One button: same principle as two buttons. After each standstill, the motor direction is reversed. Other actions for use in a Velbus system can be programmed using the Velbuslink* software. CHARACTERISTICS For general information about the installation and •...
  • Page 11 In case the VMB1BLS was not addressed in advance, this can be done afterwards as follows: • in Velbuslink, right click on a shutter channel of a VMB1BLS that needs to be addressed and select “Operate” • check which of the installed shutters goes up or down •...
  • Page 12 - 230 VAC / 16 A max. soirs. Après chaque arrêt, la direction du moteur est inversée. - 30 V DC / 12 A max. Autres actions pour utilisation dans un système Velbus peuvent • tension d’alimentation: 12..18 V DC être programmées via Velbuslink*.
  • Page 13 Si le VMB1BLS n’a pas été adressé d’avance, vous pouvez encore le faire par la suite: • pilotez dans Velbuslink le canal de volet d’un VMB1BLS à adresser (clic droit sur le canal de volet > “Piloter”) • vérifier lequel des volets installés monte ou descend •...
  • Page 14 all-guides.com...
  • Page 15 All manuals and user guides at all-guides.com Visit us at: www.VELBUS.eu Velbus , Legen Heirweg 33 - Gavere (Belgium) ® /Velbus @Velbus www.velbus.eu...