The electrodes must be installed for operation on the control unit in accordance
with the diagram below.
4.2 pH setpoint: [7.2]
The setpoint is used to set the desired pH value of the pool water. In the event that the
setpoint is undercut or exceeded, the dosing pump will be activated in accordance with
the settings. The basic setting ex works is designed for dosing pH reducing chemicals.
4.3 pH p-band: [-1.0]
This function can be used to define two key settings of the control unit:
Dosing direction for pH value:
With a negative p band [-1.00], if the setpoint is exceeded, the dosing pump is
activated. When using this setting, pH-reducing chemicals are employed.
With a positive p band [1.00], if the setpoint is undercut, the dosing pump is
activated. When using this setting, pH-elevating chemicals are employed.
Note: When changing between pH-reducing and pH-elevating water care
products, the dosing line must be rinsed with water and the inoculation valve
must be cleaned.