CCT SELECT EMERGENCY T8 INSTALLATION / CCT SELECT INSTALLATION D'URGENCE T8
fig.6
UNSWITCHED LINE
NEUTRAL
Post-Installation Verification Testing:
1
Confirm that the lamp turns on and off normally with the wall switch. The lamp should be off when the wall switch is in the off position. If the lamp is on with the wall
switch in off position, the lamp may be installed backwards in the luminaire, or the lamp holders may not be wired properly.
2
Ensure that the Charging Indicator Light is on. If the Charging Indicator Light is off, the EM Input side may not be powered properly. Check the luminaire wiring to
ensure the EM Input side is receiving power.
3
To perform an Emergency Function test. After the fixture is installed and powered on, press and hold the Test Button for 3 seconds. The lamp will enter the
Emergency mode and the charging indicator light will stay off. Then, release the test button and the lamp will quit emergency mode.
4
If the battery is depleted, the lamp may fail to illuminate. Allow 24 hours to charge and repeat the test.
5
If the Charging Indicator Light is blinking, keep the power on for both the Input Side and the EM Input Side for at least 5 minutes in case the battery is depleted.
The indicator light should be solid in standard working mode when charging. If the indicator light is still blinking, we suggest replacing with a new EM tube.
Test de Vérification Post-installation:
1
Vérifiez que la lampe s'allume et s'éteint normalement avec l'interrupteur mural. La lampe doit être éteinte lorsque l'interrupteur mural est en position d'arrêt. Si la
lampe est allumée avec l'interrupteur mural en position d'arrêt, la lampe peut être installée à l'envers dans le luminaire ou les supports de lampe peuvent ne pas être
câblés correctement.
2
Assurez-vous que le voyant de charge est allumé. Si le voyant de charge est éteint, le côté entrée EM peut ne pas être correctement alimenté. Vérifiez le câblage du
luminaire pour vous assurer que le côté entrée EM est alimenté.
3
Pour effectuer un test de fonction d'urgence. Une fois l'appareil installé et allumé, appuyez sur le bouton Test et maintenez-le enfoncé pendant 3 secondes. La lampe
entrera en mode d'urgence et le voyant de charge restera éteint. Ensuite, relâchez le bouton de test et la lampe avec quitter le mode d'urgence.
4
Si la batterie est épuisée, la lampe peut ne pas s'allumer. Attendre 24 heures pour charger et répéter le test.
5
Si le voyant de charge clignote, maintenez l'alimentation du côté entrée et du côté entrée EM pendant au moins 5 minutes au cas où la batterie serait épuisée. Le
voyant doit être solide en mode de fonctionnement normal lors de la charge. Si le voyant lumineux clignote toujours, nous suggérons de le remplacer par un nouveau
tube EM.
For testing and maintenance instruction, refer to the Test Button & Indicator Light below:
a)
Self-test function. If the emergency function is abnormal, the indicator light will blink.
b)
Automatic charging function. The Indicator Light shows charging status and full charge status.
c)
Emergency Function test. After the fixture is installed and powered on, press and hold the Test Button for 3 seconds. The lamp will enter the
Emergency mode and the charging indicator light will stay off. Then, release the test button and the lamp will quit emergency mode.
d)
Battery transportation protection function. In Emergency Mode, press the test button three times quickly, the battery will go into hibernation, and standby before
installation.
Pour les instructions de test et de maintenance, reportez-vous au bouton de test et au voyant ci-dessous:
a)
Fonction d'autotest. Si la fonction d'urgence est anormale, le voyant clignote.
b)
Fonction de charge automatique. Le voyant lumineux indique l'état de charge et l'état de charge complète.
c)
Essai de fonction d'urgence. Après l'installation sur le luminaire et la mise sous tension, maintenez enfoncé le bouton de test pendant 2 secondes, la lampe passera
en mode d'urgence ; puis relâchez le bouton de test, la lampe quittera le mode de test d'urgence.
d)
Fonction de protection du transport de la batterie. En mode d'urgence, appuyez trois fois rapidement sur le bouton de test, la batterie passera en veille prolongée et
en veille avant l'installation.
www.greencreative.com - info@greencreative.com - Tel / Fax: (866) 774-5433 -
LED tube wiring diagram without dimming
AC 120-277V
Testing Button
Charge Indicator Light
Test button
Indicator light
For model #: 15T8/4F/8CCTS/EM
Pour les produits suivants: 15T8/4F/8CCTS/EM
WALL SWITCH
Non-Shunted
/ GREENCREATIVELED
/ GClightingLED
SWITCHED LINE
AC 120-277V
NEUTRAL
CCT Select Switch
Shunted
/ GREEN-CREATIVE
An ILLUMUS Brand

Publicité

loading

Ce manuel est également adapté pour:

15t8/4f/8ccts/em-2pk