Télécharger Imprimer la page

Richell 94928 Manuel D'instruction page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
6. Examples of Installations
●To fit maximum opening
A
B
※Call out numbers are to show how to connect each Side Frame (see figures below.)
●To fit minimum
opening
Main
Unit
Type ①
Adjuster Knob
Adjuster Bolt
Type ⑤
Hexagon
Cap Nut
Bolt
Connector
Main Unit
Side Frame D
7. How to Install the Gate
Bottom bar
※The top width of the frame may be wider than the wall since the product is designed to be installed using a tension-spring effect.
If necessary, use force to make the top of the gate narrower to fit between the wall as shown in Figure 1.
Determine the desired direction for the door opening. Set the product against the wall at a perpendicular right angle as shown in Figure 2.
  Tighten the upper Adjuster Knob until the rubber of the Adjuster Knob touches the wall surface as shown in Figure 3.
Tighten the upper Adjuster Knobs on each side until clearance between the Gate Door and Main Frame is set to about 0.8" as shown in
Figure 4.
Tighten the lower Adjuster Knobs to give enough tension force. Then install the product against the wall vertically as shown in Figure 5.
●Models 94928, 94929, 94930 and 94931 are designed to fit openings 32.1 - 36.4".
Models 94932, 94933, 94934 and 94935 are designed to fit openings 32.1 - 62.8".
Add Side Frames to fit the opening in a doorway or hallway.
C
●Using Side Frame D
D
Main
Unit
Type ②
Hexagon Nut
Adjuster Knob
Adjuster Bolt
Side Frame A
Type ⑥
Side Frame D
●The bottom of the product should contact the floor for safety as shown in Figure 1.
Cautions!
●If the product has been installed correctly, the top of the gate (while looking down from
above the top) will be as straight as a line with each end aligned at a 90-degree right
angle as shown in Figure 2.
Wall
Make sure the
Make sure the
bottom of the
bottom of the
Main Frame
Main Frame
touches the
touches the
Floor. Use force
Floor. Use force
to make the top
to make the top
of the gate
of the gate
narrower.
narrower.
Figure 1
Main Unit
●Using Side Frame A, B and D
A
Main
D
B
Unit
Type ③
Side Frame B
Side Frame C
Joint
●Side Frame A has to be closest to the wall.
Side Frame B
●Do not use two of Side Frame A on the same side.
Joint
90° degree
90° degree
90° degree
90° degree
3
D
B
●Using Side Frame B, C and D
A
C
Main
Unit
Type ④
Hexagon
Cap Nut
Side Frame C
2.4" and above
Adjuster Knob
Tension
force
Less than 2.4"
Rubber
Figure 2
A
D
B
Bolt
Connector
Main Unit
Clockwise
rotation
Figure 3

Publicité

loading

Ce manuel est également adapté pour:

949299493294933