BOLLARD RETROFIT LAMP
LED-8039X345X-A
PRIOR TO INSTALLATION, PLEASE READ THE ENTIRE INSTALLATION INSTRUCTIONS
CAUTION – THESE RETROFIT LAMPS ARE DESIGNED TO OPERATE ON LINE VOLTAGE, BALLAST MUST BE BYPASSED.
SUITABLE FOR USE IN DRY OR DAMP LOCATIONS.
SUITABLE FOR USE IN ENCLOSED LUMINAIRES.
NOT FOR EMERGENCY LIGHTING.
NOT FOR USE IN ENVIRONMENTS WHERE EXPLOSIVE OR CORROSIVE GASES ARE PRESENT.
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT
INSTALLATION.
WARNING – RISK OR FIRE OR ELECTRIC SHOCK. LED RETROFIT KIT INSTALLATION REQUIRES KNOWLEDGE OF
LUMINIARES ELECTTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED
ELECTRICIAN.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK.
CONSTRUCTION FEATURE AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND/OR DRAWING AND WHERE THE
INPUT RATING OF THE RETROFIT KIT DOES NTO EXCEED THE INPUT RATING OF THE LUMINAIRE.
WARNING – TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR
OTHER SHARP OBJECTS.
FOR INSTALLATIONS IN CANADA – THIS RETROFIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE
SUITABILIY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION.
LAMPS COME WITH A 5 YEAR WARRANTY AGAINST MANUFACTURING DEFECTS.
THIS WARRANTY DOES NOT COVER PHYSICAL DAMAGE OR IMPROPER OPERATION.
INSTALLATION REQUIREMENTS
MODEL
INPUT VOLTAGE
LED-8039E345-A
120-277 VAC 50/60 Hz
LED-8039E345C-A
220-347 VAC 50/60 Hz
LED-8039M345-A
120-277 VAC 50/60 Hz
LED-8039M345C-A
220-347 VAC 50/60 Hz
INSTALLATION INSTRUCTIONS
1) Turn off power to the luminaire at switch and circuit breaker. Allow luminaire to
cool before proceeding.
2) Ensure that the luminaire and electrical inputs meet the requirements in the table.
The lamp should be installed in an enclosed fixture. Please ensure that the lamp is
protected from direct water spray and bugs.
3) If a ballast is present it must be bypassed. If desired it may be removed. Please
refer to the wiring diagram. Disconnect or cut the wires to and from the ballast.
Connect the line and neutral wires to the socket leads as shown in the wiring
diagram. Product may be installed using two hot leads if a neutral is not available.
Check that voltage meets the requirements.
4) Inspect the lamp holder for arcing or corrosion and replace if damaged.
5) Select lamp light color using the switch on the side of the lamp.
6) Screw the lamp into the lamp holder. Do not over-torque as this could cause
damage. Once the device is firmly screwed into the socket, it can be adjusted for
proper orientation by rotating counter-clockwise. After adjusting, tighten one of
the locking screws on the neck of the lamp.
7) Apply included label to the inside of the luminaire where it will be visible during re-
lamping.
8) Turn on electrical power to the luminaire and verify proper operation.
INSTALL THIS KIT ONLY IN LUMINAIRES THAT HAVE THE
LAMP
MIN. LAMP COMPARTMENT
HOLDER
DIMENSIONS
E26
4.6" x 7.3"
E39 or
4.6" x 8.0"
EX39
INSTALLATION AND USERS GUIDE
18W
LUMINAIRE
Enclosed
CONTENTS
• Lamp
• Label
• Instructions
WIRING
BALLAST MUST BE BYPASSED
LINE
BALLAST
NEUTRAL
CORRECT WIRING
NEUTRAL
LINE
3K
4K
5K
ORIENTATION
Base Up, Down or
Horizontal
LAMP HOLDER
LAMP HOLDER
WHITE
BLACK
6/12/2020