The Smoke Sensor can be battery operated. Battery life is approximately 3
years when in optimum mode. The low battery level warning is displayed in the
"Security" interface next to the icon in the "Main" tab. The device itself, separate
from the Active SmartHome Gateway, also monitors the battery level and a low
battery is signaled by a yellow flashing LED and an intermittent sound alarm.
The Smoke Sensor can signal a low battery level for approximately 30 days.
It is not possible to power the device from a battery and a VDC power
source at the same time. When using a VDC power source it is
recommended that another kind of power back-up is used. The Active
SmartHome checks the battery level twice a day.
2.2. Switching to a constant current powering mode
1.
If necessary reset the Smoke Sensor (see section 6).
2.
Disconnect the battery.
3.
Install the constant power connecting terminal (see fig. 02).
4.
Add the Smoke Sensor to the Active SmartHome Platform (see section 03).
Incorrect wiring may cause a hazard or result in damage to the device.
Label:
1.
+12 V - constant power supply terminal, 12/24 VDC.
2.
GND - ground terminal.
S mo k e S e n s o r
All manuals and user guides at all-guides.com
I n st all at io n an d O p er at io n Gu i d e