4.
Tighten the screws holding the strain relief bar in place. Also tighten the wire access
nut. This will create a water-resistant seal (Figure 11).
5.
Check to make sure all wire connections are securely fastened to the terminal strip.
Replace the wire compartment cover and re-install the two screws removed in Step 1.
SECTION 7
Completing the Installation
1.
Use a sealant appropriate for contact with the building materials present and for the
temperature requirements of the installation to prevent air leakage from unconditioned
spaces is recommended. If gaps between unit housing and ceiling are great, additional
material (backing rod, ceiling material) may be required.
4" Inline Kits: Install the grill into the inlets by squeezing the two ends of the springs
2.
together and installing them up into the slots of the fan. Push the grill up into position
(Figure 12).
Figure 12
3.
Restore power and test your installation.
Trouble
1. Fan does not operate when the switch is on.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal.
WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials.
HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase or until the original purchaser of
the product sells or transfers the product, whichever first occurs.
WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or
comparable model.
WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse, misuse,
unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay return shipping charges from Air
King following warranty repairs or replacement
ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF ORIGINAL
PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING'S LIABILITY UNDER
ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES,
CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING'S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY EXCEED
THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.
Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or limitations may not apply to
you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is required before a warranty claim will be accepted.
Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern. Please have
PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST HEATER
Installer:
Place of Purchase:
A210952017 Rev. G 12-15
Troubleshooting Guide
Probable Cause
1a.
A fuse may be blown or a circuit tripped.
1b.
Wiring is not connected properly.
1c.
Motor has stopped operating.
2a.
Obstruction in the exhaust ducting.
2b.
Speed control not set high enough.
2c.
Incorrect wiring.
3a.
Motor is loose.
3b.
Fan mounting screws too tight.
3c.
Fan damaged in shipping.
LIMITED WARRANTY
CUSTOMER SERVICE:
Toll-Free (800) 465-7300
your model number available, as well as the type and style (located on the label inside of your product).
Please do not return product to place of purchase.
www.airkinglimited.com
COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.
www.airkinglimited.com
SECTION 8
Use and Care
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
1a.
Cleaning the Grill (4" Inine Kits): Remove grill and use a mild detergent, such as
dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR
SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in
Step 2 of Section 7, to reinstall grill.
Cleaning the Grill (6" Inine Kits): With the grill in place, wipe with a damp cloth or
1b.
gently vacuum. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely
dry grill before turing the power back on.
2.
The fan's bearings are sealed and provided with an internal lubricating material, no
additional lubrication is necessary.
CALIFORNIA RESIDENTS ONLY:
WARNING:
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
WARNING:
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL
[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
REPRODUCTIVE TOXICITY.
Suggested Remedy
1a.
Replace fuse or reset circuit breaker.
1b.
Turn off power to unit. Check that all wires are connected.
1c.
Replace motor.
2a.
Check for any obstructions in the ducting. The most common are bird nests
in the roof cap or wall cap where the fan exhausts to the outside.
2b.
If a speed control is being used, confirm the setting.
2c.
Turn off power to unit. Check that all wires are connected correctly.
3a.
Turn off power to unit. Confirm unit is mounted securely to bracket.
Restore power to unit.
3b.
Turn off power to the unit. Loosen screws going through rubber grommets
3c.
Contact seller for replacement.
Installation Date:
Model Number:
MAKE SURE POWER IS SWITCHED OFF AT