M5100-PM Front Panel Features
Power Button
Power LEDs
Press and hold for
Indicates the status of the
one second to turn
rear panel outlets. The LED
Bank 2 and Bank 3
outlet bank icon will be lit
outlets ON or OFF.
when the corresponding out-
lets are turned ON. They will
flash during the startup and
shutdown process.
BANK 1
LINEAR
LINEAR
FILTER
FILTER
M5100-PM Back Panel Connection Features
Outlet Bank 3
Circuit Breaker
Automatically opens
Two switched, high-current outlets controlled by the
front panel Power Button or the DC Trigger input.
when the current load
is greater than 15
Bank 3 has a 5 second turn on delay and turns off
immediately. The High Current outlet provides power
Amps. Push to reset.
from a low impedance noise filtration circuit that does
not limit the current to your equipment. Its output is
noise isolated from all other outlet banks
HIGH CURRENT
15 AMP
CIRCUIT
BREAKER
GROUND
SWITCHED
LUG
DELAYED
MAIN POWER
120 VAC/15A
BANK 3
Main Power
Ground Lug
Must be plugged into a properly
Provides a common grounding
wired & grounded 3-wire outlet.
point for equipment with separate
ground leads.
2
All manuals and user guides at all-guides.com
Wiring OK LED
Meter/Front Panel LED
Normally On. Indicates
Dimmer
that the wall outlet is
Pushbutton control for
properly grounded and
meter and front panel
Line/Neutral polarity is
LED brightness. Cycles
correct.
between four bright-
ness settings.
BANK 2
BANK 3
WIRING
HIGH
CURRENT
OK
Digital Voltmeter
Digital LED voltmeter indicates the incoming line voltage. If line voltage drops below 90VAC, or if the
line voltage exceeds 142VAC, the display will turn off and the "unsafe voltage" indicator will flash
indicating an unsafe voltage condition.
Outlet Bank 2
Four switched outlets with linear filtration technolo-
gy (LiFT) controlled by the front panel Power
Button or the DC Trigger input. Bank 2 will turn on
immediately and turn off after 10 seconds. LiFT
EMI/RFI noise filtration is provided by a two-stage
balanced Pi filter which also provides noise isola-
tion from Outlet Banks 1 and 3.
LINEAR FILTRATION - SWITCHED
BANK 3
Bank 1 Indicator Light
Normally ON, is lit
when there is power
present on the Bank 1
receptacles.
Unsafe Voltage Indicator
USB Charging Port
Located in the Voltmeter and
For charging
is normally off. Flashes red
portable electronic
to indicate that the incoming
devices while pro-
line voltage is unsafe and the
tecting them from
unit has disconnected the
unsafe voltages. USB
power to protect your equip-
5V/5x 100 mA or
ment.
500 mA
VOLTS
Outlet Bank 1
Four always-on outlets with linear filtration technolo-
gy (LiFT). Power will only be turned off under a fault
condition. (See specifications for over-voltage and
under-voltage thresholds) Power is cleaned by a
two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.
LINEAR FILTRATION - ALWAYS ON
BANK 1
ON
BANK 1
Voltage Sense Trigger
Input
3.5mm (1/8") mono
mini-plug. Connect to
a remote trigger device
that uses a DC output
to trigger a startup/shut-
down sequence.
Note to CATV Installers:
This reminder is provided to call attention to Article 820-40 of the NEC. That article
provides specific guidelines for proper grounding. It specifies that the cable ground
shall be connected to the grounding system of the building and as close to the point
of entry as practical.
Convenience LAN
Port
Offers a bi-direction-
al Ethernet pass-thru
connection between
the front and rear
panel.
Universal TV Coaxial Jacks
3 pairs of bidirectional pro-
tection circuits optimized for
satellite, cable, and antenna
TV signal lines.
UNIVERSAL COAX PROTECTION
1
2
3
LAN 1
LAN 2
LINE IN
LINE IN
EQUIP.
LINE IN
IN
12V
TRIGGER
LAN Jacks
Phone Jacks
Protection circuits for 10/100
Protection circuits for standard
baseT Ethernet lines. Incoming
telephone or pay-per- view
LAN line MUST be plugged into
lines. Phone circuit is auto-
the LINE jack. Patch cord to the
resetting. Incoming phone
equipment MUST be plugged into
cord MUST be plugged into
the EQUIP jacks. 1 LAN jack goes
the LINE jack. Patch cords to
to the front panel output jack. 8
the equipment (satellite receiv-
wire protection, 50V clamping.
er, digital video recorder, tele-
phone, etc.) MUST be plugged
into the EQUIP jacks.
Gaming Outlet
Convenient front
panel outlet provides
surge protection for
gaming systems, digi-
tal cameras, cam-
corders, and other
devices.
M5100-PM
PHONE
EQUIP.