VENTILATOR KIT
INSTALLATION
For DCWH, DCWL, DCWN - 30" wide only
and DTWS/DSWB/DBCV Series hoods -
30" and 36" wide only, unless otherwise
specified.
1. Attach DAMPER to VENTILATOR, as shown,
using three (3) HEX SCREWS (provided).
Note: Damper flange to be captured by screw
heads.
2. Lift ventilator into position inside the hood.
3. Fasten ventilator to four (4) THREADED
STUDS, using four (4) HEX NUTS (provided).
4. Plug ventilator's POWER CORD into
RECEPTACLE inside the hood.
5. NOTE: This installation does not use
PV300217 Mounting Plate and (4) Additional
Hex Nuts. They may be discarded.
THREADED STUDS
DAMPER
HEX NUTS
TOP OF HOOD
HEX
SCREWS
RECEPTACLE
POWER
VENTILATOR
CORD
VENTILATOR KIT
INSTALLATION
For DCWH, DCWL, DCWN - 36" wide only
and VCWH Series hoods - 30" and 36"
wide only, unless otherwise specified.
1. Attach DAMPER to VENTILATOR, as shown,
using three (3) HEX SCREWS (provided).
Note: Damper flange to be captured by screw
heads.
2. Attach VENTILATOR to (4) THREADED
STUDS on MOUNTING PLATE using (4) HEX
NUTS (provided).
3. Lift ventilator into position inside the hood.
4. Fasten ventilator to four (4) THREADED
STUDS, using four (4) HEX NUTS (provided).
5. Plug ventilator's POWER CORD into
RECEPTACLE inside the hood.